The DOI matches its Crossref record.
Radiofrequency plasma deposition of oxygen‐containing films on polystyrene and poly(ethylene terephthalate) substrates improves endothelial cell growth
Abstract
Polystyrene and poly(ethylene terephthalate) substrates were modified by radiofrequency plasma deposition with organic vapors comprised of carbon, oxygen, and hydrogen (acetone, methanol, glutaraldehyde, formic acid, allyl alcohol, and ethylene oxide). The treatments resulted in the deposition of a film at least 100 Å thick containing up to 26% atomic oxygen at the surface. A high oxygen incorporation was observed for vapors with a large oxygen‐to‐carbon ratio. Bovine aortic endothelial cell growth measured on acetone, methanol, and glutaraldehyde films was linearly correlated with the oxygen content of the treated surfaces. Nitrogen was incorporated in the surface by blending nitrogen gas into the organic vapors used for plasma deposition. The resulting nitrogen‐containing substrates exhibited a high affinity for serum fibronectin but a moderate cell growth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
New Challenges in Biomaterials
Peppas, N. A., & Langer, R. (1994) · Science · doi:10.1126/science.8134835 · Cited by 1,142
Polymer surface modification by plasmas and photons
Chan, C.-M., Ko, T.-M., & Hiraoka, H. (1996) · Surface Science Reports · doi:10.1016/0167-5729(96)80003-3 · Cited by 1,074
Siow, K. S., Britcher, L., Kumar, S., & Griesser, H. J. (2006) · Plasma Processes and Polymers · doi:10.1002/ppap.200600021 · Cited by 972
Surface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800
Macromolecular plasma-chemistry: an emerging field of polymer science
DENES, F. (2004) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2004.05.001 · Cited by 374
The biocompatibility of novel starch-based polymers and composites: in vitro studies
Marques, A. P., Reis, R. L., & Hunt, J. A. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00272-1 · Cited by 347
Cook, A. D., Hrkach, J. S., Gao, N. N., Johnson, I. M., Pajvani, U. B., Cannizzaro, S. M., & Langer, R. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19970615)35:4<513::aid-jbm11>3.0.co;2-c · Cited by 320
Surface modification of polymers: chemical, biological and surface analytical challenges
Ratner, B. D. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)99218-a · Cited by 303
Self-citationTidwell, C. D., Ertel, S. I., Ratner, B. D., Tarasevich, B. J., Atre, S., & Allara, D. L. (1997) · Langmuir · doi:10.1021/la9604341 · Cited by 282
Self-citationLöpez, G. P., Ratner, B. D., Tidwell, C. D., Haycox, C. L., Rapoza, R. J., & Horbett, T. A. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260402 · Cited by 260
Self-citationA Combinatorial Approach for Polymer Design
Brocchini, S., James, K., Tangpasuthadol, V., & Kohn, J. (1997) · Journal of the American Chemical Society · doi:10.1021/ja970389z · Cited by 259
Metadata
- Authors
- Ertel, S. I., Ratner, B. D., & Horbett, T. A.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1990-12
- Volume
- 24
- Issue
- 12
- Pages
- 1637-1659
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W1983436701
- Cited by
- 160
- References
- 0
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.