Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 634

The DOI matches its Crossref record.

Protein adsorption to poly(ethylene oxide) surfaces

Gombotz, Wayne R., Guanghui, Wang, Horbett, Thomas A., Hoffman, Allan S.·1991·Journal of Biomedical Materials Research

Abstract

Surfaces containing poly(ethylene oxide) (PEO) are interesting biomaterials because they exhibit low degrees of protein adsorption and cell adhesion. In this study different molecular weight PEO molecules were covalently attached to poly(ethylene terephthalate) (PET) films using cyanuric chloride chemistry. Prior to the PEO immobilization, amino groups were introduced onto the PET films by exposing them to an allylamine plasma glow discharge. The amino groups on the PET film were next activated with cyanuric chloride and then reacted with bis‐ amino PEO. The samples were characterized by scanning electron microscopy, water contact angle measurements, gravimetric analysis, and electron spectroscopy for chemical analysis (ESCA). The adsorption of 125 I‐labeled baboon fibrinogen and bovine serum albumin was studied from buffer solutions. Gravimetric analysis indicated that the films grafted with the low‐molecularweight PEO contained many more PEO molecules than the surfaces grafted with higher‐molecular‐weight PEO. The highmolecular‐weight PEO surfaces, however, exhibited greater wettability (lower water contact angles) and less protein adsorption than the low‐molecular‐weight PEO surfaces. Adsorption of albumin and fibrinogen to the PEO surfaces decreased with increasing PEO molecular weight up to 3500. A further increase in molecular weight resulted in only slight decreases in protein adsorption. Protein adsorption studies as a function of buffer ionic strength suggest that there may be an ionic interaction between the protein and the allylamine surface. The trends in protein adsorption together with the water contact angle results and the gravimetric analysis suggest that a kind of “cooperative” water structuring around the larger PEO molecules may create an “excluded volume” of the hydrated polymer coils. This may be an important factor contributing to the observed low protein adsorption behavior.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.820251211

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 634

Metadata

Authors
Gombotz, W. R., Guanghui, W., Horbett, T. A., & Hoffman, A. S.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1991-12
Volume
25
Issue
12
Pages
1547-1562
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W1972278871
Cited by
634
References
0
FWCI
5.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Protein adsorption to poly(ethylene oxide) surfaces. https://app.cochat.ai/papers/10.1002/jbm.820251211
The paper
Gombotz, W. R., Guanghui, W., Horbett, T. A., & Hoffman, A. S. (1991). Protein adsorption to poly(ethylene oxide) surfaces. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820251211

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.