Postadsorptive transition in fibrinogen adsorbed to polyurethanes: Changes in antibody binding and sodium dodecy1 sulfate elutability
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Residence time‐dependent changes in fibrinogen after adsorption to six different polyurethanes were examined by measuring polyclonal antifibrinogen binding to the adsorbed protein. The amount of adsorbed fibrinogen that could be eluted by sodium dodecyl sulfate (SDS) was also measured. Baboon fibrinogen was first adsorbed from dilute plasma to the polymers, which were then stored in either buffer or buffered albumin solution prior to testing. Subsequently, the amount of antifibrinogen bound by the adsorbed fibrinogen was measured using a direct enzyme linked immunosorbent assay (ELISA). Alternatively, the surface with the adsorbed fibrinogen was soaked in a 3% SDS solution, and the amount of retained 125 I‐radiolabeled fibrinogen was measured. With increasing residence time, decreases in both antibody binding and the SDS elutability of the adsorbed fibrinogen occurred, but the rate of change was dependent on the polyurethane to which the fibrinogen was adsorbed. In addition, the antibody binding per unit of adsorbed fibrinogen, when measured immediately after the adsorption step, varied by approximately a factor of 3 among the various polyurethanes. When the protein‐coated surfaces were stored in buffered albumin solution rather than buffer, the decrease in the reactivity of fibrinogen with residence time did not occur on some of the surfaces. This study shows that the chemical properties of the adsorbing surface influence the rate at which adsorbed fibrinogen undergoes change. The significance of the polymer‐dependent changes in adsorbed fibrinogen with respect to blood reactions with polymers is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physicochemical characterization and in vivo blood tolerability of cast and extruded biomer
Lelah, M. D., Lambrecht, L. K., Young, B. R., & Cooper, S. L. (1983) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820170102 · Cited by 134
Cited by
Surface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800
Fibrin(ogen) mediates acute inflammatory responses to biomaterials.
Tang, L., & Eaton, J. W. (1993) · The Journal of experimental medicine · doi:10.1084/jem.178.6.2147 · Cited by 449
Molecular basis of biomaterial-mediated foreign body reactions
Hu, W.-J., Eaton, J. W., Ugarova, T. P., & Tang, L. (2001) · Blood · doi:10.1182/blood.v98.4.1231 · Cited by 431
Proteins, platelets, and blood coagulation at biomaterial interfaces
Xu, L.-C., Bauer, J. W., & Siedlecki, C. A. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.09.040 · Cited by 391
Horbett, T. A. (1993) · Cardiovascular Pathology · doi:10.1016/1054-8807(93)90054-6 · Cited by 385
Self-citation
Metadata
- Authors
- Chinn, J. A., Posso, S. E., Horbett, T. A., & Ratner, B. D.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1992-06
- Volume
- 26
- Issue
- 6
- Pages
- 757-778
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2066629576
- Cited by
- 61
- References
- 1
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.