CoChat

Effect of polyol type on the surface structure of sulfonate‐containing polyurethanes

Silver, James H., Lewis, Ken B., Ratner, Buddy D., Cooper, Stuart L. · 1993 · Journal of Biomedical Materials Research
Cited by 36

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Polyurethanes based upon polytetramethylene oxide (PTMO) as the polyol and derivatized with propyl sulfonate functionality pendant from the urethane nitrogen have previously been shown to possess good bloodcontacting properties. Other investigators have shown that sulfonated polyurethanes containing polyethylene oxide (PEO) as the soft segment are much more thrombogenic than those containing PTMO as the soft segment. In this article, the surface properties of sulfonated polyurethanes based upon either PTMO or PEO are compared. Dynamic contact angle measurements show a significant decrease in the receding angles of the sulfonated PTMO‐containing polyurethane as compared to its nonsulfonated precursor polymer. No significant difference is seen between the receding contact angles of either the sulfonated PEO‐based polyurethane or its nonsulfonated analog. Variableangle electron spectroscopy for chemical analysis (ESCA) studies of sulfonated PTMO‐based polyurethane performed at room temperature show that there is a significant decrease in sulfur content at the surface. In contrast, the sulfonated PEO‐based polyurethane showed little change in sulfur content with take‐off angle. Finally, ESCA studies of freeze‐dried surfaces show a significant increase in sulfur near the surface of the sulfonated PTMO‐based polymer as compared to vacuum‐dried samples but show no such increase for the sulfonated PEO‐based polyurethane. It is suggested that the ability of the sulfonate functionality to be expressed at the surface may explain the observed differences in blood compatibility between the sulfonated polyurethanes based upon polyols of varying hydrophilicity. © 1993 John Wiley & Sons, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.820270606

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 36

Metadata

Authors
Silver, J. H., Lewis, K. B., Ratner, B. D., & Cooper, S. L.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1993-06
Volume
27
Issue
6
Pages
735-745
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2154581470
Cited by
36
References
1
FWCI
2.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of polyol type on the surface structure of sulfonate‐containing polyurethanes. https://app.cochat.ai/papers/10.1002/jbm.820270606
The paper
Silver, J. H., Lewis, K. B., Ratner, B. D., & Cooper, S. L. (1993). Effect of polyol type on the surface structure of sulfonate‐containing polyurethanes. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820270606

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.