Abstract

Collagen from a native tissue is fixed with a polyepoxy compound (PC) for use as a new biologic prosthetic material. Prior studies have shown that this biomaterial has comparable properties with collagen fixed with glutaraldehyde (GA), and thus has great promise for biomedical applications. A prior kinetic study indicated that the reaction between the functional groups of collagen and the multifunctional epoxy EX‐313 is a 2.5th‐order reaction. The purpose of this study was to understand the mechanism of the amino acid‐PC reactions in a fixation process. Bovine arteries were fixed with a monofunctional PC (EX‐313) and a multifunctional PC (EX‐313) as a function of fixation time. A sequential fixation with a second fixative was used to identify the available remaining reactive sites from a prior fixation. The denaturation temperature (T d) was measured on each sample. Because the denaturation temperature is a direct indication of crosslinking of individual amino acids with the fixative, the increase in T d of a subsequent fixation may be indicative of the available remaining amino acids. The fixation index was measured on each sample to reflect the increase of fixation completion in a sequential fixation process. The fixation index and crosslink data also revealed that the reactive amino acids for EX‐131 and EX‐131 may not be exactly the same. The data in this study suggest that a monofunctional fixative can pre‐react with the amino acids of collagen to effectively block further fixation of collagen with a second fixative. This amino acid masking may be associated with collagen branching. Collagen branching and its effect on denaturation temperature are described. © 1994 John Wiley & Sons, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.820280604

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 86

Metadata

Authors
Tu, R., Shen, S., Lin, D., Hata, C., Thyagarajan, K., Noishiki, Y., & Quijano, R. C.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1994-06
Volume
28
Issue
6
Pages
677-684
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W1997180043
Cited by
86
References
0
FWCI
3.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fixation of bioprosthetic tissues with monofunctional and multifunctional polyepoxy compounds. https://app.cochat.ai/papers/10.1002/jbm.820280604
The paper
Tu, R., Shen, S., Lin, D., Hata, C., Thyagarajan, K., Noishiki, Y., & Quijano, R. C. (1994). Fixation of bioprosthetic tissues with monofunctional and multifunctional polyepoxy compounds. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820280604

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.