CoChat

The effect of phosphorylcholine‐coated materials on the inflammatory response and fibrous capsule formation: In vitro and in vivo observations

Goreish, Hind H., Lewis, Andrew L., Rose, Susanna, Lloyd, Andrew W. · 2004 · Journal of Biomedical Materials Research Part A
Cited by 61

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Several experiments were performed to compare the in vitro adhesion of human macrophage and granulocyte inflammatory cells to polyethylene terephthalate substrate and the same coated with a phosphorylcholine (PC)‐based polymer. The inclusion of various types of serum at different stages in the assay indicated that protein adsorption and passivation of the surface may be responsible for reducing the number of inflammatory cells adhering to the uncoated polyethylene terephthalate controls. In all of the assays performed there was a statistically significant reduction (p < 0.05; analysis of variance) of the number of inflammatory cells adhering to the PC‐coated samples, linked to the ability of these surfaces to resist protein adhesion. Implantations of PC‐coated stainless steel and high‐density polyethylene USP control samples were made in a rabbit intramuscular model. Histological examination of the number of inflammatory cells present around the implant sites 4 weeks postimplantation showed there were 40% less cells associated with the PC‐coated samples compared with control, but this was not statistically significant. Fibrous capsule thickness, however, whereas marginally less at 4 weeks, had almost completely regressed for the PC‐coated sample at 13 weeks postimplantation and was statistically thinner (p < 0.01; Mann‐Whitney U test) than the high‐density polyethylene USP control. These findings support the view that low biointeractions observed for PC‐based technology in vitro can result in reduced inflammation and foreign body reaction in vivo. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 68A: 1–9, 2004

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.10141

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Goreish, H. H., Lewis, A. L., Rose, S., & Lloyd, A. W.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2003-11-14
Volume
68A
Issue
1
Pages
1-9
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2067231144
Cited by
61
References
1
FWCI
1.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.