The DOI matches its Crossref record.
The use of a novel PLGA fiber/collagen composite web as a scaffold for engineering of articular cartilage tissue with adjustable thickness
Abstract
It has been a great challenge to make the thickness of engineered cartilage adjustable to cover the range of both partial‐thickness and full‐thickness articular cartilage defects. We developed a novel kind of composite web scaffold that could be used for tissue enginnering of articular cartilage with the thickness adjustable between 200 μm and 8 mm. The composite web showed a unique structure having web‐like collagen microsponges formed in the openings of a mechanically strong knitted mesh of poly(lactic‐co‐glycolic acid). The knitted mesh served as a skeleton reinforcing the composite web, while the web‐like collagen microsponges facilitated cell seeding, cell distribution, and tissue formation. Bovine chondrocytes cultured in the composite web showed a spatially even distribution, maintained their natural morphology, and produced cartilaginous extracellular matrices such as type II collagen and aggrecan. The thickness of the implant can be simply adjusted by laminating or rolling the web sheets. Not only did the histological structure of the engineered cartilage patches match the bovine native articular cartilage, but also their dynamic complex modulus, structural stiffness, and phase lag reached 37.8, 57.0, and 86.3% of those of native bovine articular cartilage, respectively. The composite web could be an important scaffold for tissue engineering. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 1170–1180, 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Scaffolds for bone tissue engineering: state of the art and new perspectives
Roseti, L., Parisi, V., Petretta, M., Cavallo, C., Desando, G., Bartolotti, I., & Grigolo, B. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.05.017 · Cited by 1,320
Novel chitin and chitosan nanofibers in biomedical applications
Jayakumar, R., Prabaharan, M., Nair, S. V., & Tamura, H. (2010) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.11.001 · Cited by 1,013
A Review: Electrospinning of Biopolymer Nanofibers and their Applications
Schiffman, J. D., & Schauer, C. L. (2008) · Polymer Reviews · doi:10.1080/15583720802022182 · Cited by 820
Chung, C., & Burdick, J. A. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.027 · Cited by 760
Amani, H., Arzaghi, H., Bayandori, M., Dezfuli, A. S., Pazoki‐Toroudi, H., Shafiee, A., & Moradi, L. (2019) · Advanced Materials Interfaces · doi:10.1002/admi.201900572 · Cited by 436
Metadata
- Authors
- Chen, G., Sato, T., Ushida, T., Hirochika, R., Shirasaki, Y., Ochiai, N., & Tateishi, T.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2003-11-04
- Volume
- 67A
- Issue
- 4
- Pages
- 1170-1180
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2068928522
- Cited by
- 176
- References
- 0
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The use of a novel PLGA fiber/collagen composite web as a scaffold for engineering of articular cartilage tissue with adjustable thickness. https://app.cochat.ai/papers/10.1002/jbm.a.10164
- The paper
- Chen, G., Sato, T., Ushida, T., Hirochika, R., Shirasaki, Y., Ochiai, N., & Tateishi, T. (2003). The use of a novel PLGA fiber/collagen composite web as a scaffold for engineering of articular cartilage tissue with adjustable thickness. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.10164
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.