The DOI matches its Crossref record.
Enhanced solubility of paclitaxel using water‐soluble and biocompatible 2‐methacryloyloxyethyl phosphorylcholine polymers
Abstract
The purpose of this study was to enhance the water‐solubility of paclitaxel (PTX) using an amphiphilic 2‐methacryloyloxyethyl phosphorylcholine (MPC) polymer as the solubilizer. PTX is an antineoplastic drug effective for various cancers, especially for ovarian and breast cancers. However, its solubility in aqueous medium is quite low, less than 0.1 μg/mL in water. We prepared the amphiphilic MPC polymers containing hydrophobic units to form aggregates and provide hydrophobic domains in water. The most effective polymer to dissolve the PTX was poly[MPC‐co‐n‐butyl methacrylate(BMA) (PMB30W)] with 70 mol % of the BMA unit. The inside polarity of PMB30W aggregate was the same as that of ethanol, which is a good solvent for dissolving PTX. The diameter of PMB30W aggregate containing 1 mg/mL of PTX was 50 nm in aqueous medium. The concentration of PTX in the PMB30W aqueous solution reached 5.0 mg/mL. The solution was transparent and PTX did not precipitate even when the solution was stored at room temperature for 1 month. Animal experiments indicated that the PMB30W has no adverse effect even when the polymer solution is injected into the bloodstream. From the PMB30W/PTX solution, we prepared by the solvent evaporation method a PMB30W film containing PTX with good transparency. The PMB30W film containing PTX easily dissolved in water to give a clear solution. We conclude that the water‐soluble amphiphilic MPC polymers are good solubilizers for PTX as injectable and biocompatible drug formulations. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 65A: 209–214, 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Polymeric micelles and alternative nanonized delivery vehicles for poorly soluble drugs
Lu, Y., & Park, K. (2013) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2012.08.042 · Cited by 572
Phosphorus-Containing Polymers: A Great Opportunity for the Biomedical Field
Monge, S., Canniccioni, B., Graillot, A., & Robin, J.-J. (2011) · Biomacromolecules · doi:10.1021/bm2004803 · Cited by 317
Biotin-decorated all-HPMA polymeric micelles for paclitaxel delivery
Wang, Y., van Steenbergen, M. J., Beztsinna, N., Shi, Y., Lammers, T., van Nostrum, C. F., & Hennink, W. E. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.09.013 · Cited by 66
Ayalew, L., Acuna, J., Urfano, S. F., Morfin, C., Sablan, A., Oh, M., Gamboa, A., & Slowinska, K. (2017) · ACS Medicinal Chemistry Letters · doi:10.1021/acsmedchemlett.7b00117 · Cited by 35
Metadata
- Authors
- Konno, T., Watanabe, J., & Ishihara, K.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2003-03-07
- Volume
- 65A
- Issue
- 2
- Pages
- 209-214
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2066349600
- Cited by
- 180
- References
- 0
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced solubility of paclitaxel using water‐soluble and biocompatible 2‐methacryloyloxyethyl phosphorylcholine polymers. https://app.cochat.ai/papers/10.1002/jbm.a.10481
- The paper
- Konno, T., Watanabe, J., & Ishihara, K. (2003). Enhanced solubility of paclitaxel using water‐soluble and biocompatible 2‐methacryloyloxyethyl phosphorylcholine polymers. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.10481
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.