Preparation and assessment of revised simulated body fluids
Abstract
A simulated body fluid (SBF) with ion concentrations approximately equal to those of human blood plasma has been used widely for in vitro assessment of the bioactivity of artificial materials and for the formation of bone‐like apatite on various substrates. The ion concentrations of a conventional SBF (c‐SBF) are, however, not exactly equal to those of blood plasma. In the present study, a revision of c‐SBF was made to prepare new SBFs (r‐SBF, i‐SBF, and m‐SBF) with ion concentrations equal to or closer to those of blood plasma. The ion concentrations of the r‐SBF and i‐SBF were designed to be equal to those of blood plasma in total and dissociated amounts, respectively. The m‐SBF was designed to have a total ion concentration equal to that of blood plasma, except for the concentration of HCO, which was set to the saturated level with respect to calcite. The ion concentrations and pH of the as‐prepared new SBFs were found to be equal to those of the nominal values. Upon sealed storage, the r‐SBF and i‐SBF showed no change in ion concentrations for up to 4 weeks at 5°C, and up to 2 weeks at 36.5°C, but thereafter they showed a decrease in HCO concentration and an increase in pH. Under the same storage conditions, the c‐SBF and m‐SBF showed no change in ion concentrations and pH values over a period of up to 8 weeks. These results indicate that the r‐SBF and i‐SBF are less stable than the c‐SBF and m‐SBF in terms of changes in ion concentrations relative to storage period. The m‐SBF is optimal for in vitro bioactivity assessment of artificial materials and for biomimetic production of bone‐like apatite. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 65A: 188–195, 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solutions able to reproduce in vivo surface‐structure changes in bioactive glass‐ceramic A‐W3
Kokubo, T., Kushitani, H., Sakka, S., Kitsugi, T., & Yamamuro, T. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240607 · Cited by 3,836
Self-citationHench, L. L. (1998) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1998.tb02540.x · Cited by 2,652
Plummer, L. N., & Busenberg, E. (1982) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(82)90056-4 · Cited by 1,886
Principles of Bone Biology: By Bilezikian, Raisz and Rodan. Academic Press, London, U.K., 1996
Compston, J. E. (1997) · Clinical Endocrinology · doi:10.1046/j.1365-2265.1997.2431019.x · Cited by 1,370
Bioactive glass ceramics: properties and applications
Kokubo, T. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90194-f · Cited by 1,202
Self-citationTHE CHEMICAL DYNAMICS OF BONE MINERAL
NEUMAN, W. F., & NEUMAN, M. W. (1959) · The American Journal Of The Medical Sciences · doi:10.1097/00000441-195912000-00030 · Cited by 1,032
Ca, P‐rich layer formed on high‐strength bioactive glass‐ceramic A‐W
Kokubo, T., Ito, S., Huang, Z. T., Hayashi, T., Sakka, S., Kitsugi, T., & Yamamuro, T. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240306 · Cited by 859
Self-citationChemical anatomy, physiology and pathology of extracellular fluid
Gamble, J. L. (1954) · University Microfilms International eBooks · Cited by 579
Apatite coating on ceramics, metals and polymers utilizing a biological process
Abe, Y., Kokubo, T., & Yamamuro, T. (1990) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00701082 · Cited by 394
Self-citationSolubility of Ca5{P04)3OH in the System Ca{OH)2-H3P04-H20 at 5, 15, 25, and 37 °C
McDowell, H., Gregory, T. M., & Brown, W. E. (1977) · Journal of Research of the National Bureau of Standards Section A: Physics and Chemistry · doi:10.6028/jres.081a.017 · Cited by 382
The Ionization Constant of HCO3- from 0 to 50°
Harned, H. S., & Scholes, S. R. (1941) · Journal of the American Chemical Society · doi:10.1021/ja01851a058 · Cited by 339
Apatite Coating on Organic Polymers by a Biomimetic Process
Tanahashi, M., Yao, T., Kokubo, T., Minoda, M., Miyamoto, T., Nakamura, T., & Yamamuro, T. (1994) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1994.tb04508.x · Cited by 298
Self-citationSolution effects on the surface reactions of a bioactive glass
Filgueiras, M. R., La Torre, G., & Hench, L. L. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270405 · Cited by 286
Apatite formation on the surface of ceravital‐type glass‐ceramic in the body
Ohtsuki, C., Kushitani, H., Kokubo, T., Kotani, S., & Yamamuro, T. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820251105 · Cited by 259
Self-citationPreparation and solubility of hydroxyapatite
Moreno, E. C., Gregory, T. M., & Brown, W. E. (1968) · Journal of Research of the National Bureau of Standards Section A Physics and Chemistry · doi:10.6028/jres.072a.052 · Cited by 253
Formation and growth of clusters in conventional and new kinds of simulated body fluids
Oyane, A., Onuma, K., Ito, A., Kim, H., Kokubo, T., & Nakamura, T. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10426 · Cited by 238
Self-citationThe First Ionization of Carbonic Acid in Aqueous Solutions of Sodium Chloride
Harned, H. S., & Bonner, F. T. (1945) · Journal of the American Chemical Society · doi:10.1021/ja01222a037 · Cited by 199
Bone‐bonding ability of P2O5‐Free CaO · SiO2 glasses
Ohura, K., Nakamura, T., Yamamuro, T., Kokubo, T., Ebisawa, Y., Kotoura, Y., & Oka, M. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250307 · Cited by 184
Self-citationBates, R. G., & Acree, S. F. (1943) · Journal of Research of the National Bureau of Standards · doi:10.6028/jres.030.012 · Cited by 164
Apatite-Forming Ability of Alkali-Treated Ti Metal in Body Environment
Kim, H., Miyaji, F., Kokubo, T., & Nakamura, T. (1997) · Journal of the Ceramic Society of Japan · doi:10.2109/jcersj.105.111 · Cited by 156
Self-citationKitsugi, T., Nakamura, T., Yamamura, T., et al. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820211008 · Cited by 141
Self-citationBates, R. G. (1951) · Journal of research of the National Bureau of Standards · doi:10.6028/jres.047.017 · Cited by 116
Lu (1999) · doi:10.1002/(sici)1097-4636(199908)46:2
Cited by
How useful is SBF in predicting in vivo bone bioactivity?
Kokubo, T., & Takadama, H. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.017 · Cited by 9,576
Self-citationBiomimetic Systems for Hydroxyapatite Mineralization Inspired By Bone and Enamel
Palmer, L. C., Newcomb, C. J., Kaltz, S. R., Spoerke, E. D., & Stupp, S. I. (2008) · Chemical Reviews · doi:10.1021/cr8004422 · Cited by 1,090
Eliaz, N., & Metoki, N. (2017) · Materials · doi:10.3390/ma10040334 · Cited by 1,088
Can bioactivity be tested in vitro with SBF solution?
Bohner, M., & Lemaitre, J. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.01.008 · Cited by 923
Calcium Orthophosphates in Nature, Biology and Medicine
Dorozhkin, S. V. (2009) · Materials · doi:10.3390/ma2020399 · Cited by 823
Metadata
- Authors
- Oyane, A., Kim, H., Furuya, T., Kokubo, T., Miyazaki, T., & Nakamura, T.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2003-03-07
- Volume
- 65A
- Issue
- 2
- Pages
- 188-195
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2014637539
- Cited by
- 1,117
- References
- 23
- FWCI
- 10.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.