The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Evaluation of biocompatibility of polypyrrole in vitro and in vivo
Abstract
In this study, the biocompatibility of the electrically conductive polymer polypyrrole (PPy) with nerve tissue was evaluated in vitro and in vivo. The extraction solution of PPy powder, which was synthesized chemically, was tested for acute toxicity, subacute toxicity, pyretogen, quantitative measure of cell viability, hemolysis, allergen, and micronuclei. The PPy membrane was synthesized electrochemically on the indium tin oxide conductive borosilicate glass. The dorsal root ganglia from 1–3‐day‐old Sprague‐Dawley rats were cultured above PPy membrane and observed by light or scanning electron microscopy. The PPy‐silicone tube (PPy membrane on the inner surface of the silicone tube) also synthesized electrochemically was used to bridge across 10‐mm sciatic nerve gap in rats. Twenty‐four weeks after the operation to rats, the regenerated tissues were observed by electrophysiological and histological techniques. PPy extraction solution showed no evidence of acute and subacute toxicity, pyretogen, hemolysis, allergen, and mutagenesis, and the Schwann cells from the PPy extraction solution group showed better survival rate and proliferation rate as compared with the saline solution control group. The migration of the Schwann cells and the neurite extension from dorsal root ganglia on the surface of PPy membrane‐coated glass was better than those of bare glass. There was only lightly inflammation during 6 months of the postoperation, when the PPy‐silicone tube bridged across the gap of the transected sciatic nerve. The regeneration of nerve tissue in the PPy‐silicone tube was slightly better than that in the plain silicone tube by means of electrophysiological and histological examination. The results of this study indicate that PPy has a good biocompatibility with rat peripheral nerve tissue and that PPy might be a candidate material for bridging the peripheral nerve gap. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 68A: 411–422, 2004
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Organization for Standardization
(2011) · SpringerReference · doi:10.1007/springerreference_16847 · Cited by 12,534
Handbook of conducting polymers
Skotheim, T. A., Elsenbaumer, R. L., & Reynolds, J. R. (1986) · M. Dekker eBooks · Cited by 8,079
Stimulation of neurite outgrowth using an electrically conducting polymer
Schmidt, C. E., Shastri, V. R., Vacanti, J. P., & Langer, R. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.17.8948 · Cited by 1,071
Electrically conducting polymers can noninvasively control the shape and growth of mammalian cells.
Wong, J. Y., Langer, R., & Ingber, D. E. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.8.3201 · Cited by 519
Kotwal, A. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00344-6 · Cited by 518
In vivo studies of polypyrrole/peptide coated neural probes
Cui, X. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00415-5 · Cited by 505
Collier, J. H., Camp, J. P., Hudson, T. W., & Schmidt, C. E. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(20000615)50:4<574::aid-jbm13>3.0.co;2-i · Cited by 389
Polypyrrole-heparin composites as stimulus-responsive substrates for endothelial cell growth
Garner, B., Georgevich, A., Hodgson, A. J., Liu, L., & Wallace, G. G. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199902)44:2<121::aid-jbm1>3.0.co;2-a · Cited by 279
Electrical Activity Modulates Growth Cone Guidance by Diffusible Factors
Ming, G.-L., Henley, J., Tessier-Lavigne, M., Song, H.-J., & Poo, M.-M. (2001) · Neuron · doi:10.1016/s0896-6273(01)00217-3 · Cited by 270
The development of bioartificial nerve grafts for peripheral-nerve regeneration
Heath, C. A., & Rutkowski, G. E. (1998) · Trends in Biotechnology · doi:10.1016/s0167-7799(97)01165-7 · Cited by 217
De Giglio, E., Sabbatini, L., Colucci, S., & Zambonin, G. (2000) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856200743580 · Cited by 172
A preliminary assessment of poly(pyrrole) in nerve guide studies
Williams, R. L., & Doherty, P. J. (1994) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00058978 · Cited by 166
Has electrical growth cone guidance found its potential?
McCaig, C., Rajnicek, A. M., Song, B., & Zhao, M. (2002) · Trends in Neurosciences · doi:10.1016/s0166-2236(02)02174-4 · Cited by 140
In vitro biocompatibility study of electrically conductive polypyrrole-coated polyester fabrics
Zhang, Z., Roy, R., Dugr�, F. J., Tessier, D., & Dao, L. H. (2001) · Journal of Biomedical Materials Research · Cited by 125
Tissue Reaction to Polypyrrole-Coated Polyester Fabrics: An in Vivo Study in Rats
Jiang, X., Marois, Y., Traoré, A. S., Tessier, D., Dao, L. H., Guidoin, R., & Zhang, Z. (2002) · Tissue Engineering · doi:10.1089/107632702760240553 · Cited by 124
Keeley, R., Atagi, T. A., Sabelman, E. E., Padilla, J. A., Kadlcik, S., Keeley, A., Nguyen, K. D., & Rosen, J. M. (1993) · Journal of Reconstructive Microsurgery · doi:10.1055/s-2007-1006742 · Cited by 58
Electrically induced neurite outgrowth of PC12 cells on the electrode surface
Kimura, K., Yanagida, Y., Haruyama, T., Kobatake, E., & Aizawa, M. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523221 · Cited by 52
Conducting polymers on microelectronic devices as tools for biological analyses
Livache, T., Bazin, H., & Mathis, G. (1998) · Clinica Chimica Acta · doi:10.1016/s0009-8981(98)00143-0 · Cited by 41
Stimulus History Alters Behavioral Responses of Neuronal Growth Cones
Diefenbach, T. J., Guthrie, P. B., & Kater, S. B. (2000) · Journal of Neuroscience · doi:10.1523/jneurosci.20-04-01484.2000 · Cited by 33
Biostability of electrically conductive polyester fabrics: An in vitro study
Jiang, X., Tessier, D., Dao, L. H., et al. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10240 · Cited by 28
Cited by
Conductive polymers: Towards a smart biomaterial for tissue engineering
Balint, R., Cassidy, N. J., & Cartmell, S. H. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.015 · Cited by 1,777
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Electrically conductive polymers and composites for biomedical applications
Kaur, G., Adhikari, R., Cass, P., Bown, M., & Gunatillake, P. (2015) · RSC Advances · doi:10.1039/c5ra01851j · Cited by 836
Polypyrrole-coated electrospun PLGA nanofibers for neural tissue applications
Lee, J. Y., Bashur, C. A., Goldstein, A. S., & Schmidt, C. E. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.04.042 · Cited by 735
Ghasemi-Mobarakeh, L., Prabhakaran, M. P., Morshed, M., Nasr-Esfahani, M. H., Baharvand, H., Kiani, S., Al-Deyab, S. S., & Ramakrishna, S. (2011) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.383 · Cited by 698
Metadata
- Authors
- Wang, X., Gu, X., Yuan, C., Chen, S., Zhang, P., Zhang, T., Yao, J., Chen, F., & Chen, G.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2003-12-17
- Volume
- 68A
- Issue
- 3
- Pages
- 411-422
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1552981362
- Cited by
- 453
- References
- 20
- FWCI
- 3.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.