The DOI matches its Crossref record.
Synthesis, analytical characterization, and osteoblast adhesion properties on RGD-grafted polypyrrole coatings on titanium substrates
Abstract
The covalent attachment of an Arg-Gly-Asp (RGD) containing peptide to polypyrrole(PPy)-coated titanium substrates has been investigated in order to develop a bioactive material of potential use in orthopedic fields. Polypyrrole has been employed as the coating polymer because of its suitability to be electrochemically grown directly onto metallic substrates of different shapes, leading to remarkably adherent films. The synthetic peptide Cys-Gly-(Arg-Gly-Asp)-Ser-Pro-Lys, containing the cell-adhesive region of fibronectin (RGD), has been grafted to the polymer substrate via the cysteine residue using a procedure recently developed in the authors laboratory. The effectiveness of grafting was monitored by X-ray photoelectron spectroscopy (XPS), which assessed the presence of the peptide grafted onto the polymer surface exploiting the cysteine sulfur as target element. Neonatal rat calvarial osteoblasts were attached to RGD-modified PPy-coated Ti substrates at levels significantly greater than on unmodified PPy-coated Ti and glass coverslip substrates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
RGD modified polymers: biomaterials for stimulated cell adhesion and beyond
Hersel, U., Dahmen, C., & Kessler, H. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00343-0 · Cited by 2,582
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Evaluation of biocompatibility of polypyrrole in vitro and in vivo
Wang, X., Gu, X., Yuan, C., Chen, S., Zhang, P., Zhang, T., Yao, J., Chen, F., & Chen, G. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.20065 · Cited by 453
Review paper: Progress in the Field of Conducting Polymers for Tissue Engineering Applications
Bendrea, A.-D., Cianga, L., & Cianga, I. (2011) · Journal of Biomaterials Applications · doi:10.1177/0885328211402704 · Cited by 322
Metadata
- Authors
- De Giglio, E., Sabbatini, L., Colucci, S., & Zambonin, G.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 2000-01
- Volume
- 11
- Issue
- 10
- Pages
- 1073-1083
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W1994782249
- Cited by
- 172
- References
- 0
- FWCI
- 4.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Synthesis, analytical characterization, and osteoblast adhesion properties on RGD-grafted polypyrrole coatings on titanium substrates. https://app.cochat.ai/papers/10.1163/156856200743580
- The paper
- De Giglio, E., Sabbatini, L., Colucci, S., & Zambonin, G. (2000). Synthesis, analytical characterization, and osteoblast adhesion properties on RGD-grafted polypyrrole coatings on titanium substrates. Journal of Biomaterials Science, Polymer Edition. https://doi.org/10.1163/156856200743580
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.