Macrophage responses to vascular stent coatings
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Diamond‐like carbon (DLC) films have been proposed as potential coatings for blood‐contacting devices. In this study, tetrahedral amorphous carbon (ta‐C) films deposited by filtered cathodic vacuum arc system (FCVA) were compared with commercially deposited polyurethane coatings (PU) and uncoated stainless steel samples. X‐ray reflectivity (XRR) measurements were performed to check density and thickness of the ta‐C coatings, and contact angles measurements were used to assess surface wettability. J774 macrophages were used to assess the cell responses to the materials. Cell number, metabolic activity, and hydrogen peroxide production were measured by using biochemical assays, and the cell attachment and morphology were determined by using scanning electron microscopy and confocal laser scanning microscopy. Wettability measurements showed that of the materials, the stainless steel was the most hydrophilic, and the ta‐C coatings were the most hydrophobic. Although the initial attachment and morphology did not appear to be dependent on the wettability, the cell numbers did increase with increasing wettability. Macrophages on the stainless steel samples were the most active in producing hydrogen peroxide. These data show that ta‐C samples performed as well as commercial PU‐coated samples in blocking cell reactions to the substrate and may prove to be effective coatings for blood‐contacting materials. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res 70A: 380–390, 2004
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reactive Oxygen Species as Mediators of Signal Transduction in Cardiovascular Disease
Abe, J.-I., & Berk, B. C. (1998) · Trends in Cardiovascular Medicine · doi:10.1016/s1050-1738(97)00133-3 · Cited by 260
Integrin signalling in neutrophils and macrophages
Berton, G., & Lowell, C. A. (1999) · Cellular Signalling · doi:10.1016/s0898-6568(99)00003-0 · Cited by 224
Cited by
The biocompatibility of carbon nanotubes
Smart, S. K., Cassady, A. I., Lu, G. Q., & Martin, D. J. (2006) · Carbon · doi:10.1016/j.carbon.2005.10.011 · Cited by 1,011
Biomedical applications of diamond‐like carbon coatings: A review
Roy, R. K., & Lee, K. (2007) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30768 · Cited by 496
The role of nanometer and sub-micron surface features on vascular and bone cell adhesion on titanium
Khang, D., Lu, J., Yao, C., Haberstroh, K. M., & Webster, T. J. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.009 · Cited by 437
Chamberlain, L. M., Godek, M. L., Gonzalez‐Juarrero, M., & Grainger, D. W. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31930 · Cited by 112
Metadata
- Authors
- Ball, M., O'Brien, A., Dolan, F., Abbas, G., & McLaughlin, J. A.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2004-06-28
- Volume
- 70A
- Issue
- 3
- Pages
- 380-390
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1963613272
- Cited by
- 36
- References
- 2
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Macrophage responses to vascular stent coatings. https://app.cochat.ai/papers/10.1002/jbm.a.30066
- The paper
- Ball, M., O'Brien, A., Dolan, F., Abbas, G., & McLaughlin, J. A. (2004). Macrophage responses to vascular stent coatings. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.30066
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.