CoChat

Controlling osteopontin orientation on surfaces to modulate endothelial cell adhesion

Liu, Lingyun, Chen, Shengfu, Giachelli, Cecilia M., Ratner, Buddy D., Jiang, Shaoyi · 2005 · Journal of Biomedical Materials Research Part A
Cited by 84

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Osteopontin (OPN) is an important extracellular matrix protein that has been shown to impact wound healing, inflammation, and the foreign body reaction, and has been identified as a potential surface component for engineered biomaterials. OPN contains the arginine‐glycine‐aspartic acid (RGD) moiety that has been shown to mediate cell adhesion through interactions with integrins. In its preferred orientation and conformation on a surface, the functional domains of OPN will be presented to cells to the greatest extent. However, control of protein orientation and conformation is still challenging. In this work, we investigated OPN adsorption and cell adhesion to the OPN layer on self‐assembled monolayers (SAMs) of alkanethiols terminated with various functional groups and on a gold surface. The four SAM terminal groups studied were CH 3, OH, NH 2, and COOH, representing hydrophobic, hydrophilic but neutral, positively charged, and negatively charged surfaces, respectively. Surface plasmon resonance biosensor and atomic force microscopy were used to characterize the adsorption of OPN on these surfaces. An in vitro cell adhesion assay of bovine aortic endothelial cells was performed to test the functionality of OPN on various SAMs. Surface plasmon resonance results showed that the amount of protein adsorbed on the NH 2 surface is close to a monolayer and similar to that on the COOH surface, consistent with the atomic force microscopy results. However, based on cell adhesion experiments, both cell count and average cell spreading area on the NH 2 surface are much higher than those on the COOH surface. From these results, it is suggested that the orientation and conformation of OPN on a positively charged NH 2 surface is more favorable for cell adhesion and spreading than on a negatively charged COOH surface. The surface coverage of bovine aortic endothelial cells on the surfaces studied decreased in the following order: NH 2 > Au > CH 3 > COOH > OH whereas the mean cell spreading area decreased in the following order: NH 2 > Au > CH 3 > COOH. Our studies show that surface properties will alter OPN behavior on surfaces, thus influencing cell interactions. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.30221

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Liu, L., Chen, S., Giachelli, C. M., Ratner, B. D., & Jiang, S.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2005-05-26
Volume
74A
Issue
1
Pages
23-31
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W1979272007
Cited by
84
References
2
FWCI
3.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.