Controlled release of heparin from polypyrrole‐poly(vinyl alcohol) assembly by electrical stimulation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A surface modification technique was developed for the covalent immobilization of poly(vinyl alcohol) (PVA)‐heparin hydrogel onto electrically conductive polypyrrole (PPY) film with the objective of achieving controlled release of heparin. First, aldehyde groups were introduced onto PPY film through poly(ethylene glycol) monomethacrylate graft copolymerization and subsequent oxidation in acetic anhydride and dimethyl sulfoxide mixture. Then, the prepared PVA‐heparin hydrogel was cast onto the PPY film and covalently immobilized to the film through the reaction between the aldehyde groups on the PPY film and the hydroxyl groups of PVA. X‐ray photoelectron spectroscopy was used to characterize the surface‐modified film after each stage. The strong attachment of the PVA‐heparin layer on the PPY film was confirmed by peel test and scanning electron microscopy. The release behavior of heparin from the substrate with and without electrical stimulation was studied and the experimental results showed that the heparin release rate from the prepared substrate using an electric current of 3.5 mA is twofold higher than that without current. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res 73A: 171–181, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heparin release from thermosensitive polymer coatings: in vivo studies
Gutowska, A., Bae, Y. H., Jacobs, H., Mohammad, F., Mix, D., Feijen, J., & Kim, S. W. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290705 · Cited by 76
Cited by
Conductive polymers: Towards a smart biomaterial for tissue engineering
Balint, R., Cassidy, N. J., & Cartmell, S. H. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.015 · Cited by 1,777
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Conductive Polymers: Opportunities and Challenges in Biomedical Applications
Nezakati, T., Seifalian, A., Tan, A., & Seifalian, A. M. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00275 · Cited by 977
One-dimensional conducting polymer nanocomposites: Synthesis, properties and applications
Lu, X., Zhang, W., Wang, C., Wen, T.-C., & Wei, Y. (2011) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.07.010 · Cited by 644
Review on Conducting Polymers and Their Applications
Das, T. K., & Prusty, S. (2012) · Polymer-Plastics Technology and Engineering · doi:10.1080/03602559.2012.710697 · Cited by 621
Metadata
- Authors
- Li, Y., Neoh, K. G., & Kang, E. T.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2005-03-09
- Volume
- 73A
- Issue
- 2
- Pages
- 171-181
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2050047062
- Cited by
- 137
- References
- 1
- FWCI
- 2.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Controlled release of heparin from polypyrrole‐poly(vinyl alcohol) assembly by electrical stimulation. https://app.cochat.ai/papers/10.1002/jbm.a.30286
- The paper
- Li, Y., Neoh, K. G., & Kang, E. T. (2005). Controlled release of heparin from polypyrrole‐poly(vinyl alcohol) assembly by electrical stimulation. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.30286
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.