Controlled release of heparin from polypyrrole‐poly(vinyl alcohol) assembly by electrical stimulation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A surface modification technique was developed for the covalent immobilization of poly(vinyl alcohol) (PVA)‐heparin hydrogel onto electrically conductive polypyrrole (PPY) film with the objective of achieving controlled release of heparin. First, aldehyde groups were introduced onto PPY film through poly(ethylene glycol) monomethacrylate graft copolymerization and subsequent oxidation in acetic anhydride and dimethyl sulfoxide mixture. Then, the prepared PVA‐heparin hydrogel was cast onto the PPY film and covalently immobilized to the film through the reaction between the aldehyde groups on the PPY film and the hydroxyl groups of PVA. X‐ray photoelectron spectroscopy was used to characterize the surface‐modified film after each stage. The strong attachment of the PVA‐heparin layer on the PPY film was confirmed by peel test and scanning electron microscopy. The release behavior of heparin from the substrate with and without electrical stimulation was studied and the experimental results showed that the heparin release rate from the prepared substrate using an electric current of 3.5 mA is twofold higher than that without current. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res 73A: 171–181, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heparin release from thermosensitive polymer coatings: in vivo studies
Gutowska, A., Bae, Y. H., Jacobs, H., Mohammad, F., Mix, D., Feijen, J., & Kim, S. W. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290705 · Cited by 76
Cited by
Conductive polymers: Towards a smart biomaterial for tissue engineering
Balint, R., Cassidy, N. J., & Cartmell, S. H. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.015 · Cited by 1,777
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Conductive Polymers: Opportunities and Challenges in Biomedical Applications
Nezakati, T., Seifalian, A., Tan, A., & Seifalian, A. M. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00275 · Cited by 977
One-dimensional conducting polymer nanocomposites: Synthesis, properties and applications
Lu, X., Zhang, W., Wang, C., Wen, T.-C., & Wei, Y. (2011) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.07.010 · Cited by 644
Review on Conducting Polymers and Their Applications
Das, T. K., & Prusty, S. (2012) · Polymer-Plastics Technology and Engineering · doi:10.1080/03602559.2012.710697 · Cited by 621
Electrochemically controlled drug delivery based on intrinsically conducting polymers
Svirskis, D., Travas-Sejdic, J., Rodgers, A., & Garg, S. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.03.023 · Cited by 442
Applications of conducting polymers and their issues in biomedical engineering
Ravichandran, R., Sundarrajan, S., Venugopal, J. R., Mukherjee, S., & Ramakrishna, S. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0120.focus · Cited by 429
3D printing of electrically conductive hydrogels for tissue engineering and biosensors – A review
Distler, T., & Boccaccini, A. R. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.08.044 · Cited by 326
Electrically Controlled Drug Delivery from Biotin‐Doped Conductive Polypyrrole
George, P. M., LaVan, D. A., Burdick, J. A., Chen, C. ‐., Liang, E., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501242 · Cited by 320
Anticancer Activity of Chitosan, Chitosan Derivatives, and Their Mechanism of Action
Adhikari, H. S., & Yadav, P. N. (2018) · International Journal of Biomaterials · doi:10.1155/2018/2952085 · Cited by 313
Gomez, N., & Schmidt, C. E. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31047 · Cited by 306
Polypyrrole-coated electrodes for the delivery of charge and neurotrophins to cochlear neurons
Richardson, R. T., Wise, A. K., Thompson, B. C., Flynn, B. O., Atkinson, P. J., Fretwell, N. J., Fallon, J. B., Wallace, G. G., Shepherd, R. K., Clark, G. M., et al. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.01.015 · Cited by 304
Biomimetic electrochemistry from conducting polymers. A review
Otero, T. F., Martinez, J. G., & Arias-Pardilla, J. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.03.097 · Cited by 292
Biomaterials Approach to Expand and Direct Differentiation of Stem Cells
Chai, C., & Leong, K. W. (2007) · Molecular Therapy · doi:10.1038/sj.mt.6300084 · Cited by 284
Radke, D., Jia, W., Sharma, D., Fena, K., Wang, G., Goldman, J., & Zhao, F. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701461 · Cited by 256
Richardson, R. T., Thompson, B., Moulton, S., Newbold, C., Lum, M. G., Cameron, A., Wallace, G., Kapsa, R., Clark, G., & O’Leary, S. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.09.008 · Cited by 251
Conductive PANi/PEGDA Macroporous Hydrogels For Nerve Regeneration
Guarino, V., Alvarez‐Perez, M. A., Borriello, A., Napolitano, T., & Ambrosio, L. (2013) · Advanced Healthcare Materials · doi:10.1002/adhm.201200152 · Cited by 217
Conducting Polymers, Hydrogels and Their Composites: Preparation, Properties and Bioapplications
Tomczykowa, M., & Plonska-Brzezinska, M. (2019) · Polymers · doi:10.3390/polym11020350 · Cited by 205
Optimizing PANi doped electroactive substrates as patches for the regeneration of cardiac muscle
Borriello, A., Guarino, V., Schiavo, L., Alvarez-Perez, M. A., & Ambrosio, L. (2011) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-011-4259-x · Cited by 204
“, muscle, myocardium) which respond to electrical impulses, demonstrates the success of variously doped CPs to entrap/ release biological molecules as therapeutic proteins and drugs [18–20] or to transfer charge from a biochemical reaction [21].”
BackgroundElectrical regulation of Schwann cells using conductive polypyrrole/chitosan polymers
Huang, J., Hu, X., Lu, L., Ye, Z., Zhang, Q., & Luo, Z. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32511 · Cited by 204
Stimuli‐Responsive Biomaterials: Scaffolds for Stem Cell Control
Gelmi, A., & Schutt, C. E. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202001125 · Cited by 204
Biomaterials‐Based Electronics: Polymers and Interfaces for Biology and Medicine
Muskovich, M., & Bettinger, C. J. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201200071 · Cited by 182
Tandon, B., Magaz, A., Balint, R., Blaker, J. J., & Cartmell, S. H. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.12.012 · Cited by 176
“Amongst others, dexamethasone [68], heparin [69], dopamine 172”
Green, R. A., Lovell, N. H., & Poole-Warren, L. A. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.06.030 · Cited by 170
Yin, A., Luo, R., Li, J., Mo, X., Wang, Y., & Zhang, X. (2017) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2017.01.045 · Cited by 45
Metadata
- Authors
- Li, Y., Neoh, K. G., & Kang, E. T.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2005-03-09
- Volume
- 73A
- Issue
- 2
- Pages
- 171-181
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2050047062
- Cited by
- 137
- References
- 1
- FWCI
- 2.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.