Rheological and recovery properties of poly(ethylene glycol) diacrylate hydrogels and human adipose tissue
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The viscosity and elastic and viscous moduli of poly(ethylene glycol) diacrylate (PEGDA) hydrogels and human abdominal adipose tissue are measured as a function of shear rate and frequency. Results indicate that both materials exhibit shear thinning and are viscoelastic in nature. Rheological tests suggest that the hydrogels become firmer as strain and frequency increase. Adipose tissue, however, begins to fail at higher strains and frequencies. This behavior is confirmed by measuring the complex modulus of both materials as a function of strain. Recovery properties are also measured for each material as a function of deformation. Although PEGDA hydrogels are able to recover up to 78% of their original height after 15% deformation, adipose tissue is not able to recover over the range of deformations tested. The frequencies and strains over which the tests are conducted are those physiologically experienced by the human body. The hydrogels are able to withstand this range of forces and, hence, are appropriate for use as a soft tissue filler material. In addition, the hydrogels swell 38.1% ± 0.9% independent of surface area. The complex modulus of hydrogels of varying polymer concentrations is also measured as a function of strain to determine the effects of changing polymer content. These results indicate that as polymer content increases, the hydrogels become firmer due to the higher number of polymer chains and behave more elastically. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res 73A: 313–319, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rubinstein, M., & Colby, R. H. (2003) · doi:10.1093/oso/9780198520597.001.0001 · Cited by 5,686
Cited by
Growth Factors, Matrices, and Forces Combine and Control Stem Cells
Discher, D. E., Mooney, D. J., & Zandstra, P. W. (2009) · Science · doi:10.1126/science.1171643 · Cited by 2,667
Stimulus-responsive hydrogels: theory, modern advances, and applications
Koetting, M. C., Peters, J. T., Steichen, S. D., & Peppas, N. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2015.04.001 · Cited by 1,191
Mondschein, R. J., Kanitkar, A., Williams, C. B., Verbridge, S. S., & Long, T. E. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.06.005 · Cited by 475
Age-related vascular stiffening: causes and consequences
Kohn, J. C., Lampi, M. C., & Reinhart-King, C. A. (2015) · Frontiers in Genetics · doi:10.3389/fgene.2015.00112 · Cited by 440
“The healthy human intima has been reported to have an elastic modulus of 34.4 kPa and is considered a compliant material, with an elastic modulus similar to adipose tissue and lower than muscle (Lundkvist et al., 1996; Engler et al., 2004; Patel et al., 2005).”
BackgroundInfluentialBuxboim, A., Ivanovska, I. L., & Discher, D. E. (2010) · Journal of Cell Science · doi:10.1242/jcs.041186 · Cited by 399
Metadata
- Authors
- Patel, P. N., Smith, C. K., & Patrick, C. W.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2005-04-15
- Volume
- 73A
- Issue
- 3
- Pages
- 313-319
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1983824091
- Cited by
- 144
- References
- 1
- FWCI
- 0.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.