Successful peripheral nerve regeneration is still limited in artificial conduits, especially for long lesion gaps. In this study, porous poly(L‐lactide‐co‐DL‐lactide, 75:25) (PLA) conduits were manufactured with 16 poly(L‐lactide) (PLLA) microfilaments aligned inside the lumen. Fourteen and 18 mm lesion gaps were created in a rat sciatic nerve lesion model. To evaluate the combined effect of permeable PLA conduits and microfilament bundles on axon growth, four types of implants were tested for each lesion gap: PLA conduits with 16 filaments; PLA conduits without filaments; silicone conduits with 16 filaments; and silicone conduits without filaments. Ten weeks following implantation, regeneration within the distal nerve was compared between corresponding groups. Antibodies against the markers S100, calcitonin gene related peptide (CGRP), RMDO95, and P0 were used to identify Schwann cells, unmyelinated axons, myelinated axons, and myelin, respectively. Results demonstrated that the filament scaffold enhanced tissue cable formation and Schwann cell migration in all groups. The filament scaffold enhanced axonal regeneration toward the distal stump, especially across long lesion gaps, but significance was only achieved with PLA conduits. When compared to corresponding silicone conduits, permeable PLA conduits enhanced myelinated axon regeneration across both lesion gaps and achieved significance only in combination with filament scaffolds. Myelin staining indicated PLA conduits supported axon myelination with better myelin quantity and quality when compared to silicone conduits. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.30432

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 136

Metadata

Authors
Cai, J., Peng, X., Nelson, K. D., Eberhart, R., & Smith, G. M.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2005-08-08
Volume
75A
Issue
2
Pages
374-386
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2067938476
Cited by
136
References
3
FWCI
1.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Permeable guidance channels containing microfilament scaffolds enhance axon growth and maturation. https://app.cochat.ai/papers/10.1002/jbm.a.30432
The paper
Cai, J., Peng, X., Nelson, K. D., Eberhart, R., & Smith, G. M. (2005). Permeable guidance channels containing microfilament scaffolds enhance axon growth and maturation. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.30432

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.