The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Nanoscale topography modulates corneal epithelial cell migration
Abstract
The purpose of this study was to evaluate the effect of surface topographic features that mimic the corneal epithelial basement membrane on cell migration. We used electron‐beam and X‐ray lithography and reactive ion etching to pattern silicon wafers with pitches (groove width plus ridge width) of nano‐ and microscale dimensions (pitches ranged from 400 to 4000 nm). Additionally, polyurethane patterned surfaces were created by replication molding techniques to allow for real‐time imaging of migrating cells. Individual SV40‐transformed human corneal epithelial cells frequently aligned with respect to the underlying surface patterns and migrated almost exclusively along grooves and ridges of all pitches. Direction of migration of individual cells on smooth surfaces was random. In cell dispersion assays, colonies of cells migrated out from initially circular zones predominantly along grooves and ridges, although there was some migration perpendicular to the ridges. On smooth surfaces, cells migrated radially, equally in all directions, maintaining circular colony shapes. We conclude that substratum features resembling the native basement membrane modulate corneal epithelial cell migration. These findings have relevance to the maintenance of corneal homeostasis and wound healing, as well as to the evolution of strategies in tissue engineering, corneal prosthesis development, and cell culture material fabrication. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cell Migration: A Physically Integrated Molecular Process
Lauffenburger, D. A., & Horwitz, A. F. (1996) · Cell · doi:10.1016/s0092-8674(00)81280-5 · Cited by 3,915
Electron microscopy of the canine corneal basement membranes
Abrams, G. A., Bentley, E., Nealey, P. F., & Murphy, C. J. (2002) · Cells Tissues Organs · doi:10.1159/000047929 · Cited by 70
Self-citation
Cited by
Engineering Substrate Topography at the Micro‐ and Nanoscale to Control Cell Function
Bettinger, C. J., Langer, R., & Borenstein, J. T. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200805179 · Cited by 1,258
Progress in corneal wound healing
Ljubimov, A. V., & Saghizadeh, M. (2015) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.002 · Cited by 872
The interaction of cells and bacteria with surfaces structured at the nanometre scale
Anselme, K., Davidson, P., Popa, A. M., Giazzon, M., Liley, M., & Ploux, L. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.04.001 · Cited by 827
Li, Y., Xiao, Y., & Liu, C. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00654 · Cited by 598
Matrix nanotopography as a regulator of cell function
Kim, D.-H., Provenzano, P. P., Smith, C. L., & Levchenko, A. (2012) · Journal of Cell Biology · doi:10.1083/jcb.201108062 · Cited by 575
Metadata
- Authors
- Diehl, K. A., Foley, J. D., Nealey, P. F., & Murphy, C. J.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2005-08-16
- Volume
- 75A
- Issue
- 3
- Pages
- 603-611
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1161873545
- Cited by
- 197
- References
- 2
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanoscale topography modulates corneal epithelial cell migration. https://app.cochat.ai/papers/10.1002/jbm.a.30467
- The paper
- Diehl, K. A., Foley, J. D., Nealey, P. F., & Murphy, C. J. (2005). Nanoscale topography modulates corneal epithelial cell migration. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.30467
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.