The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A novel bioactive porous CaSiO3 scaffold for bone tissue engineering
Abstract
The aim of this study was to fabricate bioactive porous CaSiO 3 scaffolds and examine their effects on proliferation and differentiation of osteoblast‐like cells. In this study, porous CaSiO 3 scaffolds were obtained by sintering a ceramic slip‐coated polymer foam at 1350°C. X‐ray diffraction (XRD) of the scaffolds indicated that the products were essentially pure α‐CaSiO 3. The obtained scaffolds had a well‐interconnected porous structure with pore sizes ranging from several micrometers to more than 100 μm and porosities of 88.5 ± 2.8%. The in vitro bioactivity of the scaffolds was investigated by soaking them in simulated body fluid (SBF) for 7 days and then characterizing them by scanning electron microscopy (SEM) and energy‐dispersive spectroscopy (EDS) analysis. The results indicated that hydroxyapatite (HAp) was formed on the surface of the scaffolds. In addition, the scaffolds were incubated in Ringer's solution at 37°C to study the in vitro degradation by measurement of weight loss after incubation, which showed that the CaSiO 3 scaffolds were degradable. The cellular responses to the scaffolds were assessed in terms of cell proliferation and differentiation. Osteoblast‐like cells were seeded into the CaSiO 3 scaffolds. SEM observations showed that there was significant cell adhesion, as the cells spread and grew in the scaffolds. In addition, the proliferation rate and alkaline phosphatase (ALP) activity of the cells in the scaffolds were improved as compared to the controls. These studies demonstrate initial in vitro cell compatibility and their potential application to bone tissue engineering. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reffitt, D. M., Ogston, N., Jugdaohsingh, R., Cheung, H. F. J., Evans, B. A. J., Thompson, R. P. H., Powell, J. J., & Hampson, G. N. (2003) · Bone · doi:10.1016/s8756-3282(02)00950-x · Cited by 876
Cited by
Reconstruction of calvarial defect of rabbits using porous calcium silicate bioactive ceramics
Xu, S., Lin, K., Wang, Z., Chang, J., Wang, L., Lu, J., & Ning, C. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.013 · Cited by 430
Self-citationThe incorporation of strontium and zinc into a calcium–silicon ceramic for bone tissue engineering
Zreiqat, H., Ramaswamy, Y., Wu, C., Paschalidis, A., Lu, Z., James, B., Birke, O., McDonald, M., Little, D., & Dunstan, C. R. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.024 · Cited by 299
Wang, C., Lin, K., Chang, J., & Sun, J. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.09.021 · Cited by 281
Self-citation3D bioprinting of skin: a state-of-the-art review on modelling, materials, and processes
Vijayavenkataraman, S., Lu, W. F., & Fuh, J. Y. H. (2016) · Biofabrication · doi:10.1088/1758-5090/8/3/032001 · Cited by 273
Recent advances and future perspectives of sol–gel derived porous bioactive glasses: a review
Deshmukh, K., Kovářík, T., Křenek, T., Docheva, D., Stich, T., & Pola, J. (2020) · RSC Advances · doi:10.1039/d0ra04287k · Cited by 262
Metadata
- Authors
- Ni, S., Chang, J., & Chou, L.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2005-11
- Volume
- 76A
- Issue
- 1
- Pages
- 196-205
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2063046629
- Cited by
- 193
- References
- 1
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.