Thermally responsive polymeric micelles self‐assembled by amphiphilic polyphosphazene with poly(N‐isopropylacrylamide) and ethyl glycinate as side groups: Polymer synthesis, characterization, and in vitro drug release study
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Thermally responsive amphiphilic poly(N‐isopropylacrylamide) (PNIPAm)‐grafted‐polyphosphazene (PNIPAm‐g‐PPP) was synthesized by stepwise cosubstitution of chlorine atoms on polymer backbones with amino‐terminated NIPAm oligomers and ethyl glycinate (GlyEt). Polymer structure was confirmed by FT‐IR, 1 H NMR, elemental analysis, and GPC. The thermosensitivity of PNIPAm‐g‐PPP aqueous solution was investigated by turbidity method. The lower critical solution temperature (LCST) of PNIPAm‐g‐PPP was observed to be ∼30°C in water, while it was 24°C in 0.1 M PBS (pH 7.4). Micellization behavior of PNIPAm‐g‐PPP in aqueous solution was characterized by fluorescence probe technique, TEM, and DLS. The critical micelle concentration (CMC), thus, determined was 0.0187 g/L. Both TEM and DLS measurement suggested that the diameter of micelles was ∼190 nm at 20°C. Diflunisal (DIF)‐loaded micelles were prepared by dialysis method. In vitro release test at various temperatures was also performed to study the effect of temperature on the drug release profiles. It was demonstrated that DIF release from PNIPAm‐g‐PPP micelles was slower at the temperature of 37°C than that at 4°C. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Block copolymer micelles for drug delivery: design, characterization and biological significance
Kataoka, K., Harada, A., & Nagasaki, Y. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00124-1 · Cited by 3,506
Chung, J. E., Yokoyama, M., Yamato, M., Aoyagi, T., Sakurai, Y., & Okano, T. (1999) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00029-2 · Cited by 599
Kohori, F., Sakai, K., Aoyagi, T., Yokoyama, M., Sakurai, Y., & Okano, T. (1998) · Journal of Controlled Release · doi:10.1016/s0168-3659(98)00023-6 · Cited by 273
Cited by
Physical stimuli-responsive polymeric micelles for anti-cancer drug delivery
Rapoport, N. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.009 · Cited by 1,002
Thermo-sensitive polymeric micelles based on poly (N-isopropylacrylamide) as drug carriers
Wei, H., Cheng, S.-X., Zhang, X.-Z., & Zhuo, R.-X. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.05.002 · Cited by 718
Matanović, M. R., Kristl, J., & Grabnar, P. A. (2014) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2014.06.029 · Cited by 247
“…addition, much effort has been devoted to designing and preparing thermoresponsive polymeric micelles as delivery matrices for controlled drug release (Chiappetta and Sosnik, 2007; Chung et al., 1999; Kim et al., 2000; Nakayama et al., 2006; Wang et al., 2014; Wei et al., 2006; Zhang et al., 2006).”
BackgroundQiu, L. Y., & Bae, Y. H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.05.035 · Cited by 238
Self-citationChang, C., Wei, H., Feng, J., Wang, Z.-C., Wu, X.-J., Wu, D.-Q., Cheng, S.-X., Zhang, X.-Z., & Zhuo, R.-X. (2009) · Macromolecules · doi:10.1021/ma900492v · Cited by 114
Metadata
- Authors
- Zhang, J. X., Qiu, L. Y., Jin, Y., & Zhu, K. J.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2005-12-12
- Volume
- 76A
- Issue
- 4
- Pages
- 773-780
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2162219608
- Cited by
- 60
- References
- 3
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.