The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Mineralization of hydroxyapatite in electrospun nanofibrous poly(L‐lactic acid) scaffolds
Abstract
A highly porous electrospun poly(L‐lactic acid) (PLLA) nanofibrous scaffold was used as a matrix for mineralization of hydroxyapatite. The mineralization process could be initiated by immersing the electrospun scaffold in the simulated body fluids (SBF) at 37°C for varying periods of time. Scanning electron microscopy (SEM), energy‐dispersive spectroscopy (EDS), wide‐angle X‐ray diffraction (WAXD), Fourier transform infrared (FTIR), and Raman spectroscopy were used to characterize the composition and the structure of the deposited mineral on the nanofiber surface. Results indicated that the mineral phase was a carbonated apatite with thin flake‐like nanostructures. The effects of functional groups on the scaffold surface and anionic additives in the incubation fluids on the nucleation and growth of the mineral were investigated. It was found that a minuscule amount of anionic additives (e.g., citric acid and poly‐L‐aspartic acid) in the SBF could effectively inhibit the mineral growth. Surface modification of the scaffold was carried out by hydrolysis of PLLA scaffold in NaOH aqueous solution, where carboxylic acid groups were produced without compromising the scaffold integrity. The mineralization process from modified PLLA electrospun scaffolds was significantly enhanced because the calcium ions can bind to the carboxylate groups on the fiber surface. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
THE CHEMICAL DYNAMICS OF BONE MINERAL
NEUMAN, W. F., & NEUMAN, M. W. (1959) · The American Journal Of The Medical Sciences · doi:10.1097/00000441-195912000-00030 · Cited by 1,032
Cited by
Haider, A., Haider, S., & Kang, I.-K. (2018) · Arabian Journal of Chemistry · doi:10.1016/j.arabjc.2015.11.015 · Cited by 1,861
Polymeric Scaffolds in Tissue Engineering Application: A Review
Dhandayuthapani, B., Yoshida, Y., Maekawa, T., & Kumar, D. S. (2011) · International Journal of Polymer Science · doi:10.1155/2011/290602 · Cited by 1,773
Complexity in biomaterials for tissue engineering
Place, E. S., Evans, N. D., & Stevens, M. M. (2009) · Nature Materials · doi:10.1038/nmat2441 · Cited by 1,728
Surface-functionalized electrospun nanofibers for tissue engineering and drug delivery
Yoo, H. S., Kim, T. G., & Park, T. G. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.07.007 · Cited by 1,095
Synthetic polymer scaffolds for tissue engineering
Place, E. S., George, J. H., Williams, C. K., & Stevens, M. M. (2009) · Chemical Society Reviews · doi:10.1039/b811392k · Cited by 815
Metadata
- Authors
- Chen, J., Chu, B., & Hsiao, B. S.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2006-06-30
- Volume
- 79A
- Issue
- 2
- Pages
- 307-317
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2045482198
- Cited by
- 239
- References
- 2
- FWCI
- 8.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.