The DOI matches its Crossref record.
In vivo corrosion behavior of Mg‐Mn‐Zn alloy for bone implant application
Abstract
Magnesium alloy has been implanted in rats to investigate the in vivo degradation behavior of magnesium for bone implant application. After 9 weeks postoperation, 100% implants were fixed and no inflammation was observed. Histological analysis showed new bone was formed around magnesium implant and no difference was found in the histological microstructure of the new bone and the cortical bone. A degradation or reaction layer, which was mainly composed of Ca, P, O, and Mg, was formed on the surface of magnesium alloy implants. High Ca content in the degradation layer displayed that magnesium could promote the deposition of Ca. Residual area calculation has showed that 10–17% magnesium alloy implant has been degraded in vivo. Compared with that of the controlled rats, no increase in serum magnesium and no disorder of kidney were observed after 15 weeks postoperation. After 18 weeks postoperation, 100% magnesium implants were fixed and no inflammation was observed. About 54% magnesium implant has degraded in vivo. Element analysis showed that Zn and Mn in Mg‐Mn‐Zn alloy distributed homogeneously in the residual magnesium implant, the degradation layer, and the surrounding bone tissue after 18 weeks implantation, indicating that Zn and Mn elements were easily absorbed by bioenvironment. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res 2007
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Novel Magnesium Alloys Developed for Biomedical Application: A Review
Li, N., & Zheng, Y. (2013) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2013.02.005 · Cited by 744
Biodegradable Metals for Cardiovascular Stent Application: Interests and New Opportunities
Moravej, M., & Mantovani, D. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12074250 · Cited by 600
Wong, H. M., Yeung, K. W. K., Lam, K. O., Tam, V., Chu, P. K., Luk, K. D. K., & Cheung, K. M. C. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.111 · Cited by 579
Mg and Mg alloys: How comparable are in vitro and in vivo corrosion rates? A review
Sanchez, A. H. M., Luthringer, B. J. C., Feyerabend, F., & Willumeit, R. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.11.048 · Cited by 503
Jamesh, M., Kumar, S., & Sankara Narayanan, T. S. N. (2011) · Corrosion Science · doi:10.1016/j.corsci.2010.10.011 · Cited by 262
Metadata
- Authors
- Xu, L., Yu, G., Zhang, E., Pan, F., & Yang, K.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2007-06-04
- Volume
- 83A
- Issue
- 3
- Pages
- 703-711
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1972757170
- Cited by
- 520
- References
- 0
- FWCI
- 9.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo corrosion behavior of Mg‐Mn‐Zn alloy for bone implant application. https://app.cochat.ai/papers/10.1002/jbm.a.31273
- The paper
- Xu, L., Yu, G., Zhang, E., Pan, F., & Yang, K. (2007). In vivo corrosion behavior of Mg‐Mn‐Zn alloy for bone implant application. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.31273
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.