Reduced medical infection related bacterial strains adhesion on bioactive RGD modified titanium surfaces: A first step toward cell selective surfaces
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Ideally, implants should inhibit nonspecific protein adsorption, bacterial adhesion, and at the same time, depending on the final application be selective toward cellular adhesion and spreading for all or only selected cell types. Poly(L‐lysine)‐grafted‐poly(ethylene glycol) (PLL‐g‐PEG) polymers have been shown to adsorb from aqueous solution onto negatively charged metal oxide surfaces, reducing protein adsorption as well as fibroblast, osteoblast and epithelial cell adhesion significantly. PLL‐g‐PEG can be functionalized with bioligands such as RGD (Arg‐Gly‐Asp), which then restores host cell adhesion, but the surface remains resistant to nonspecific protein adsorption. Previously, it was also shown that both nonfunctionalized PLL‐g‐PEG and RGD‐peptide functionalized PLL‐g‐PEG reduced the adhesion of Staphylococcus aureus to titanium (Ti) surfaces. The present study looked at the effect of other implant associated infection relevant bacteria, Staphylococcus epidermidis, Streptococcus mutans and Pseudomonas aeruginosa towards the same surface chemistries. The different surfaces were exposed to the bacteria for 1–24 h, and bacteria surface density was evaluated using scanning electron microscopy (SEM) and fluorescence light microscopy (FM). The adhesion of all bacteria strains tested was reduced on Ti surfaces coated with PLL‐g‐PEG compared to uncoated Ti surfaces even in the presence of RGD. The percentage reduction in bacterial adhesion over the 24‐h culture time investigated was 88%–98%, depending on the bacteria type. Therefore, coating surfaces with PLL‐g‐PEG/PEG‐RGD allows cells such as fibroblasts and osteoblasts to attach but not bacteria, resulting in a selective biointeractive pattern that may be useful on medical implants. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2008
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biofilms: Survival Mechanisms of Clinically Relevant Microorganisms
Donlan, R. M., & Costerton, J. W. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.2.167-193.2002 · Cited by 6,644
Influence of Substratum Characteristics on the Attachment of a Marine Pseudomonad to Solid Surfaces
Fletcher, M., & Loeb, G. I. (1979) · Applied and Environmental Microbiology · doi:10.1128/aem.37.1.67-72.1979 · Cited by 587
Cited by
Implant infections: adhesion, biofilm formation and immune evasion
Arciola, C. R., Campoccia, D., & Montanaro, L. (2018) · Nature Reviews Microbiology · doi:10.1038/s41579-018-0019-y · Cited by 2,241
Surface hydration: Principles and applications toward low-fouling/nonfouling biomaterials
Chen, S., Li, L., Zhao, C., & Zheng, J. (2010) · Polymer · doi:10.1016/j.polymer.2010.08.022 · Cited by 1,677
Review of titanium surface modification techniques and coatings for antibacterial applications
Chouirfa, H., Bouloussa, H., Migonney, V., & Falentin-Daudré, C. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.10.036 · Cited by 1,031
Biomaterial-Associated Infection: Locating the Finish Line in the Race for the Surface
Busscher, H. J., van der Mei, H. C., Subbiahdoss, G., Jutte, P. C., van den Dungen, J. J. A. M., Zaat, S. A. J., Schultz, M. J., & Grainger, D. W. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004528 · Cited by 707
Antibiofouling polymer interfaces: poly(ethylene glycol) and other promising candidates
Lowe, S., O'Brien-Simpson, N. M., & Connal, L. A. (2015) · Polymer Chemistry · doi:10.1039/c4py01356e · Cited by 557
Metadata
- Authors
- Maddikeri, R. R., Tosatti, S., Schuler, M., Chessari, S., Textor, M., Richards, R. G., & Harris, L. G.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2007-07-06
- Volume
- 84A
- Issue
- 2
- Pages
- 425-435
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2012961465
- Cited by
- 150
- References
- 2
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reduced medical infection related bacterial strains adhesion on bioactive RGD modified titanium surfaces: A first step toward cell selective surfaces. https://app.cochat.ai/papers/10.1002/jbm.a.31323
- The paper
- Maddikeri, R. R., Tosatti, S., Schuler, M., Chessari, S., Textor, M., Richards, R. G., & Harris, L. G. (2008). Reduced medical infection related bacterial strains adhesion on bioactive RGD modified titanium surfaces: A first step toward cell selective surfaces. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.31323
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.