CoChat

Reduced medical infection related bacterial strains adhesion on bioactive RGD modified titanium surfaces: A first step toward cell selective surfaces

Maddikeri, R.R., Tosatti, S., Schuler, M., Chessari, S., Textor, M., Richards, R.G., Harris, L.G. · 2008 · Journal of Biomedical Materials Research Part A
Cited by 150

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Ideally, implants should inhibit nonspecific protein adsorption, bacterial adhesion, and at the same time, depending on the final application be selective toward cellular adhesion and spreading for all or only selected cell types. Poly(L‐lysine)‐grafted‐poly(ethylene glycol) (PLL‐g‐PEG) polymers have been shown to adsorb from aqueous solution onto negatively charged metal oxide surfaces, reducing protein adsorption as well as fibroblast, osteoblast and epithelial cell adhesion significantly. PLL‐g‐PEG can be functionalized with bioligands such as RGD (Arg‐Gly‐Asp), which then restores host cell adhesion, but the surface remains resistant to nonspecific protein adsorption. Previously, it was also shown that both nonfunctionalized PLL‐g‐PEG and RGD‐peptide functionalized PLL‐g‐PEG reduced the adhesion of Staphylococcus aureus to titanium (Ti) surfaces. The present study looked at the effect of other implant associated infection relevant bacteria, Staphylococcus epidermidis, Streptococcus mutans and Pseudomonas aeruginosa towards the same surface chemistries. The different surfaces were exposed to the bacteria for 1–24 h, and bacteria surface density was evaluated using scanning electron microscopy (SEM) and fluorescence light microscopy (FM). The adhesion of all bacteria strains tested was reduced on Ti surfaces coated with PLL‐g‐PEG compared to uncoated Ti surfaces even in the presence of RGD. The percentage reduction in bacterial adhesion over the 24‐h culture time investigated was 88%–98%, depending on the bacteria type. Therefore, coating surfaces with PLL‐g‐PEG/PEG‐RGD allows cells such as fibroblasts and osteoblasts to attach but not bacteria, resulting in a selective biointeractive pattern that may be useful on medical implants. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2008

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.31323

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Maddikeri, R. R., Tosatti, S., Schuler, M., Chessari, S., Textor, M., Richards, R. G., & Harris, L. G.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2007-07-06
Volume
84A
Issue
2
Pages
425-435
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2012961465
Cited by
150
References
2
FWCI
4.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.