The DOI matches its Crossref record.
Enhanced osteoblast functions on anodized titanium with nanotube‐like structures
Abstract
Previous studies have demonstrated increased osteoblast (bone‐forming cells) adhesion on titanium and Ti‐6Al‐4V anodized to possess nanometer features compared with their unanodized counterparts. In this study, osteoblast long‐term functions (specifically, synthesis of intracellular proteins, synthesis of intracellular collagen, alkaline phosphatase activity, and deposition of calcium‐containing minerals) were determined on titanium anodized to possess either heterogeneous nanoparticles or ordered nanotubes. Titanium was anodized in dilute hydrofluoric acid at 20 V for 20 min to possess nanotubes, while titanium was anodized at 10 V for 20 min to possess nanoparticles. Most importantly, results showed that calcium deposition significantly increased on anodized titanium with nanotube‐like structures compared with unanodized titanium and anodized titanium with nanoparticulate structures after 21 days of osteoblast culture. In this manner, the results of the present in vitro study indicated that anodization might be a promising quick and inexpensive method to modify the surface of titanium‐based implants to induce better bone cell functions important for orthopedic applications. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res 2008
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Antibacterial coatings on titanium implants
Zhao, L., Chu, P. K., Zhang, Y., & Wu, Z. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31463 · Cited by 866
Engineering biocompatible implant surfaces
Bauer, S., Schmuki, P., von der Mark, K., & Park, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.09.001 · Cited by 780
The relationship between the nanostructure of titanium surfaces and bacterial attachment
Puckett, S. D., Taylor, E., Raimondo, T., & Webster, T. J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.09.081 · Cited by 683
Self-citationSurface characteristics of dental implants: A review
Rupp, F., Liang, L., Geis-Gerstorfer, J., Scheideler, L., & Hüttig, F. (2018) · Dental Materials · doi:10.1016/j.dental.2017.09.007 · Cited by 585
Zhao, L., Mei, S., Chu, P. K., Zhang, Y., & Wu, Z. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.014 · Cited by 465
The role of nanometer and sub-micron surface features on vascular and bone cell adhesion on titanium
Khang, D., Lu, J., Yao, C., Haberstroh, K. M., & Webster, T. J. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.009 · Cited by 437
Self-citationNanoscale engineering of biomimetic surfaces: cues from the extracellular matrix
von der Mark, K., Park, J., Bauer, S., & Schmuki, P. (2010) · Cell and Tissue Research · doi:10.1007/s00441-009-0896-5 · Cited by 343
TiO2 nanotubes for bone regeneration
Brammer, K. S., Frandsen, C. J., & Jin, S. (2012) · Trends in Biotechnology · doi:10.1016/j.tibtech.2012.02.005 · Cited by 326
Bone regeneration performance of surface-treated porous titanium
Amin Yavari, S., van der Stok, J., Chai, Y. C., Wauthle, R., Tahmasebi Birgani, Z., Habibovic, P., Mulier, M., Schrooten, J., Weinans, H., & Zadpoor, A. A. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.054 · Cited by 297
Nanoscale surface modifications of medically relevant metals: state-of-the art and perspectives
Variola, F., Brunski, J. B., Orsini, G., Tambasco de Oliveira, P., Wazen, R., & Nanci, A. (2011) · Nanoscale · doi:10.1039/c0nr00485e · Cited by 260
Spiller, D., Mirtelli, C., Losi, P., Briganti, E., Sbrana, S., Counoupas, C., Kull, S., Tonlorenzi, S., & Soldani, G. (2009) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-009-3823-0 · Cited by 15
Metadata
- Authors
- Yao, C., Slamovich, E. B., & Webster, T. J.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2007-08-09
- Volume
- 85A
- Issue
- 1
- Pages
- 157-166
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2162417834
- Cited by
- 208
- References
- 0
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.