In vitro evaluation of the PEtU-PDMS material immunocompatibility: the influence of surface topography and PDMS content
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
The aim of the present work is to evaluate the in vitro immunocompatibility of an elastomeric material with feasible applications in the cardiovascular field. In particular, since it is well known that surface chemistry and topography play a key role in the foreign body response, their influence on human monocytes was evaluated. The material, constituted by a poly(ether)urethane (PEtU) and a polydimethylsiloxane (PDMS), was synthesized to manufacture films and small-diameter vascular grafts with three different surface topographical features, smooth, rough and porous, and siloxane rates, 10, 30 and 40. Human THP-1 monocytes have been cultured for 72 h on the films and human blood has been circulating for 2 h into the grafts to assess leukocyte adhesion and cytokine releases. Materials extracts were utilized to evaluate monocyte apoptosis. Smooth films showed lower cell adhesion degrees than rough and porous ones. All the PEtU-PDMS (poly(ether)urethane-polydimethylsiloxane) films and vascular grafts induced a narrow inflammatory response, as demonstrated by slight cytokine secretion levels, in particular samples with the highest PDMS contents (30 and 40%) induced the lowest IL-1b secretion. Moreover, an absence of monocyte apoptosis advises that the negligible release values have not to be ascribed to material toxicity. In the end, surface topography showed to affect only monocyte adhesion while siloxane content the cytokine release. Therefore, the possibility to modify the above tested parameters during material synthesis and manufacture could allow to bound the inflammatory potency of the PEtU-PDMS devices and render them excellent candidates for cardiovascular reconstruction.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recent studies show that macrophage activation and FBGC formation respond to differing polymer fiber diameter [32, 33], surface roughness [34, 35] and geometry [36].”
From Characterization of topographical effects on macrophage behavior in a foreign body response model (2010) · cites this paper as [35]
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1×
“The evaluation of cytokine secretion is one of the most important indicators of the foreign body response since this event may affect the implant outcome over time [ 32 ].”
BackgroundBiological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465 · cited 1×
“This process can trigger leukocyte activation and phagocytosis, macrophage fusion into giant cells, and extracellular release of leukocyte products and lead to material degradation and lost of functionality [ 19 , 20]; the molecular basis of leukocyte binding on organic polymers is poorly elucidated, but the participa…”
BackgroundEffects of surface wettability and contact time on protein adhesion to biomaterial surfaces
Xu, L.-C., & Siedlecki, C. A. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.032 · Cited by 715
Jones, J. A., Chang, D. T., Meyerson, H., Colton, E., Kwon, I. K., Matsuda, T., & Anderson, J. M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31221 · Cited by 352 · cited 1×
“Implantation and blood-material interaction studies over the past three decades have indicated that material surface chemistry and micro-topography influence cell responses in terms of adhesion, apoptosis and activation; these events may affect the ultimate fate of implanted biomedical devices [ 16 , 17].”
BackgroundIn vitro and in vivo interactions of cells with biomaterials
Ziats, N. P., Miller, K. M., & Anderson, J. M. (1988) · Biomaterials · doi:10.1016/0142-9612(88)90063-4 · Cited by 350 · cited 1×
“This process can trigger leukocyte activation and phagocytosis, macrophage fusion into giant cells, and extracellular release of leukocyte products and lead to material degradation and lost of functionality [19, 20 ]; the molecular basis of leukocyte binding on organic polymers is poorly elucidated, but the participat…”
BackgroundZhao, Q., Topham, N., Anderson, J. M., Hiltner, A., Lodoen, G., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250205 · Cited by 318 · cited 1×
“adherent macrophages may fuse to form foreign body giant cells: the role of these cells is not still clearly understood but it seems that they may concentrate degradative and phagocytic properties leading to structural and chemical damage of the implant [ 4 ].”
BackgroundRefai, A. K., Textor, M., Brunette, D. M., & Waterfield, J. D. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30075 · Cited by 296 · cited 1×
“Besides the well-documented effects of material chemistry on the function of cells [5], it is currently accepted that surface topography influences the cell response, e.g., modulating macrophage production of cytokines and chemokines [ 6 ].”
BackgroundBiomaterial surface chemistry dictates adherent monocyte/macrophage cytokine expression in vitro
Brodbeck, W. G., Nakayama, Y., Matsuda, T., Colton, E., Ziats, N. P., & Anderson, J. M. (2002) · Cytokine · doi:10.1006/cyto.2002.1048 · Cited by 268 · cited 2×
“In the present work, the release of IL-1b, IL-6, TNF-a, and IL-10, the major monocyte pro- and anti- inflammatory cytokines with pleiotropic biological activities [ 2 , 33], was measured in static and dynamic conditions.”
BackgroundThe influence of micro-topography on cellular response and the implications for silicone implants
Von Recum, A. F., & Van Kooten, T. G. (1996) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856295x00698 · Cited by 251 · cited 1×
“The adhesion of inflammatory cells, especially monocytes/macrophages, is dictated by the types of adsorbed proteins that covered the material surface immediately after implant; this especially depends on material wettability [23], surface texture and roughness [ 24 ], and chemistry [25, 26].”
BackgroundBiomaterial adherent macrophage apoptosis is increased by hydrophilic and anionic substrates in vivo
Brodbeck, W. G., Patel, J., Voskerician, G., Christenson, E., Shive, M. S., Nakayama, Y., Matsuda, T., Ziats, N. P., & Anderson, J. M. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.162124199 · Cited by 245
Cited by
Characterization of topographical effects on macrophage behavior in a foreign body response model
Chen, S., Jones, J. A., Xu, Y., Low, H.-Y., Anderson, J. M., & Leong, K. W. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.074 · Cited by 389
“Recent studies show that macrophage activation and FBGC formation respond to differing polymer fiber diameter [32,33], surface roughness [34,35] and geometry [36].”
Saino, E., Focarete, M. L., Gualandi, C., Emanuele, E., Cornaglia, A. I., Imbriani, M., & Visai, L. (2011) · Biomacromolecules · doi:10.1021/bm200248h · Cited by 285
Pergal, M. V., Brkljačić, J. M., Tovilović-Kovačević, G., Ostojić, S., Gođevac, D. M., Vasiljević-Radović, D. G., & Djonlagić, J. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35071 · Cited by 58
Navas-Gómez, K., & Valero, M. F. (2020) · Materials · doi:10.3390/ma13153250 · Cited by 37
A simple and effective approach to produce tubular polysaccharide‐based hydrogel scaffolds
de Souza, F. C. B., Camasão, D. B., de Souza, R. F. B., Drouin, B., Mantovani, D., & Moraes, Â. M. (2019) · Journal of Applied Polymer Science · doi:10.1002/app.48510 · Cited by 32
Metadata
- Authors
- Spiller, D., Mirtelli, C., Losi, P., Briganti, E., Sbrana, S., Counoupas, C., Kull, S., Tonlorenzi, S., & Soldani, G.
- Affiliations
- Istituto di Fisiologia Clinica (IT)
- University of Pisa (IT)
- Corresponding author
- Spiller, D.
- Venue
- Journal of Materials Science: Materials in Medicine
- Published
- 2009-09-16
- Volume
- 20
- Issue
- 12
- Pages
- 2511-2520
- ISSN
- 0957-4530 (ISSN-L)
- 1573-4838
- OpenAlex
- W1969947694
- Cited by
- 15
- References
- 34
- Citations by year
- 2026: 1 · 2024: 1 · 2021: 1 · 2020: 2 · 2019: 1 · 2018: 1 · 2016: 1 · 2014: 2 · 2013: 1
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Materials Science Materials in Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Lubrizol
- Topics
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Keywords
- polyether polyurethane, polydimethylsiloxane, immunocompatibility, surface topography, vascular grafts, THP-1 cells, leukocyte adhesion, cytokine production, IL-1β, monocyte apoptosis, porous surfaces, foreign body reaction, biodegradable elastomers
- MeSH terms
- Biocompatible Materials, Cell Adhesion, Cell Line, Dimethylpolysiloxanes, Humans, Monocytes, Nylons, Polyurethanes, Surface Properties, Cytokines
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vitro evaluation of the PEtU-PDMS material immunocompatibility: the influence of surface topography and PDMS content. https://app.cochat.ai/papers/10.1007/s10856-009-3823-0
- The paper
- Spiller, D., Mirtelli, C., Losi, P., Briganti, E., Sbrana, S., Counoupas, C., Kull, S., Tonlorenzi, S., & Soldani, G. (2009). In vitro evaluation of the PEtU-PDMS material immunocompatibility: the influence of surface topography and PDMS content. Journal of Materials Science: Materials in Medicine. https://doi.org/10.1007/s10856-009-3823-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.