Surface chemistry influences implant‐mediated host tissue responses
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Implant‐mediated fibrotic reactions are detrimental to the performance of encapsulated cells, implanted drug release devices, and sensors. To improve the implant function and longevity, recent research has emphasized the need for inducing alterations in cellular responses. Although material surface functional groups have been shown to be potent in affecting cellular activity in vitro and short‐term in vivo responses, these groups appear to have little influence on long‐term in vivo fibrotic reactions, possibly as a result of insufficient interactions between recruited host cells and functional groups on the implants. To maximize the influence of functionality on cells, and to mimic drug release microspheres, functionalized micron‐sized particles were created and tested for their ability in modulating tissue responses to biomaterial implants. In this work, the surfaces of polypropylene particles were controllably coated with four different functional groups, specifically OH, NH 2, CFx, and COOH, using a radio frequency glow discharge plasma polymerization technique. The effect of these surface functionalities on host tissue responses were then evaluated using a mice subcutaneous implantation model. Major differences were observed in contrasting tissue response to the different chemistries. Surfaces with OH and NH 2 surface groups induced the thickest fibrous capsule accompanied with the greatest cellular infiltration into the implants. In contrast, surfaces with CFx and COOH exhibited the least inflammatory/fibrotic responses and cellular infiltrations. The present results clearly demonstrate that, by increasing the available functionalized surface area and spatial distribution, the effect of surface chemistry on tissue reactivity can be substantially enhanced. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res 2008
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507
Keselowsky, B. G., Collard, D. M., & Garcı́a, A. J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.062 · Cited by 627
Molecular basis of biomaterial-mediated foreign body reactions
Hu, W.-J., Eaton, J. W., Ugarova, T. P., & Tang, L. (2001) · Blood · doi:10.1182/blood.v98.4.1231 · Cited by 431
Self-citationZhao, Q., Topham, N., Anderson, J. M., Hiltner, A., Lodoen, G., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250205 · Cited by 318 · cited 2×
“[18] To generate surfaces with better tissue compatibility, many surface modification techniques, including physical modifications, chemical modifications, and radiation,[18,19] have been developed to alter the physical and chemical characteristics of the biomaterials.”
Background
Cited by
Surface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800
Self-citationBiomaterials: Foreign Bodies or Tuners for the Immune Response?
Mariani, E., Lisignoli, G., Borzì, R. M., & Pulsatelli, L. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20030636 · Cited by 706
“However, negatively charged carboxylated surfaces smooth inflammatory reactions [186,190,196] and trigger alterations in the migratory behavior and function of circulating macrophages, thus abrogating macrophage-mediated inflammatory activity and promoting regulatory T cell phenotypes [189].”
BackgroundThe pathology of the foreign body reaction against biomaterials
Klopfleisch, R., & Jung, F. (2017) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35958 · Cited by 524
Metwally, S., & Stachewicz, U. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.109883 · Cited by 382
Immunomodulatory Biomaterials for Tissue Repair
Whitaker, R., Hernaez-Estrada, B., Hernandez, R. M., Santos-Vizcaino, E., & Spiller, K. L. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00895 · Cited by 338
Metadata
- Authors
- Kamath, S., Bhattacharyya, D., Padukudru, C., Timmons, R. B., & Tang, L.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2007-11-16
- Volume
- 86A
- Issue
- 3
- Pages
- 617-626
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2025607694
- Cited by
- 132
- References
- 4
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surface chemistry influences implant‐mediated host tissue responses. https://app.cochat.ai/papers/10.1002/jbm.a.31649
- The paper
- Kamath, S., Bhattacharyya, D., Padukudru, C., Timmons, R. B., & Tang, L. (2008). Surface chemistry influences implant‐mediated host tissue responses. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.31649
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.