Biocompatibility and gelation of chitosan–glycerol phosphate hydrogels
The DOI matches its Crossref record.
Abstract
The aim of this study was to evaluate the cytotoxicity and gelation of thermosensitive chitosan‐β‐glycerol phosphate (GP) solutions, which undergo sol–gel transition around body temperature. Chitosan 0.5–2% (w/v) mixed with GP 5–20% (w/v) solutions all gel at 37°C and possess pH around the physiological range. High GP and chitosan concentrations result in faster gelation time. Extracts of all chitosan concentrations mixed with or without 5% (w/v) GP and 2% (w/v) chitosan combined with 10% (w/v) GP demonstrated up to 34% increase in proliferation rate of goat bone marrow derived mesenchymal stem cells when compared with control medium. Extracts from all other chitosan‐GP combinations resulted in reduced cell proliferation relative to control medium. Increasing GP content in the gel resulted in a linear increase in the osmolality of the extracts in contact with the gels. The results of this study indicate that chitosan‐GP is a biocompatible hydrogel, extracts of which can stimulate mesenchymal stem cell proliferation at certain concentrations. This material is therefore a promising vehicle for cell encapsulation and injectable tissue‐engineering applications. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res 2008
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chitosan-based scaffolds for bone tissue engineering
Levengood, S. K. L., & Zhang, M. (2014) · Journal of Materials Chemistry B · doi:10.1039/c4tb00027g · Cited by 672
In situ forming implants — an attractive formulation principle for parenteral depot formulations
Kempe, S., & Mäder, K. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.04.016 · Cited by 323
Wang, L., & Stegemann, J. P. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.131 · Cited by 309
Mirahmadi, F., Tafazzoli-Shadpour, M., Shokrgozar, M. A., & Bonakdar, S. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.07.043 · Cited by 232
In Situ Forming Chitosan Hydrogels Prepared via Ionic/Covalent Co-Cross-Linking
Moura, M. J., Faneca, H., Lima, M. P., Gil, M. H., & Figueiredo, M. M. (2011) · Biomacromolecules · doi:10.1021/bm200731x · Cited by 208
Metadata
- Authors
- Ahmadi, R., & de Bruijn, J. D.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2007-11-27
- Volume
- 86A
- Issue
- 3
- Pages
- 824-832
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2075913023
- Cited by
- 135
- References
- 0
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biocompatibility and gelation of chitosan–glycerol phosphate hydrogels. https://app.cochat.ai/papers/10.1002/jbm.a.31676
- The paper
- Ahmadi, R., & de Bruijn, J. D. (2008). Biocompatibility and gelation of chitosan–glycerol phosphate hydrogels. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.31676
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.