The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Calcium phosphate‐DNA nanoparticle gene delivery from alginate hydrogels induces in vivo osteogenesis
Abstract
There is a significant need for improved therapy for bone regeneration. The delivery of recombinant bone morphogenetic proteins has been approved for clinical use to promote osteogenesis, but still has limitations such as expense, degradation of the proteins in vivo and difficulties retaining protein at the site of injury. Localized gene delivery is a promising alternative therapy, as it would allow sustained expression of specific osteoinductive growth factors by cells near the damaged site. We have engineered an injectable system for localized, sustained nonviral gene delivery from alginate hydrogels containing preosteoblastic cells and calcium phosphate–DNA nanoparticles. The nanoparticles utilized in this report are stable, on the order of 100 nm, and have a high DNA incorporation efficiency (>66%). When the nanoparticles were incorporated in alginate hydrogels, sustained release of DNA was observed. Furthermore, MC3T3‐E1 preosteoblast cells exhibited the capacity to form bony tissue in as little as two and half weeks when mixed with DNA nanoparticles encoding for BMP‐2 into the alginate hydrogels and injected subcutaneously in the backs of mice. This injectable, minimally invasive gene delivery system may be efficacious in bone regeneration applications. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res, 2010
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Mechanism of Uptake of Biodegradable Microparticles in Caco-2 Cells Is Size Dependent
Desai, M. P., Labhasetwar, V., Walter, E., Levy, R. J., & Amidon, G. L. (1997) · Pharmaceutical Research · doi:10.1023/a:1012126301290 · Cited by 858
Cited by
Alginate: Properties and biomedical applications
Lee, K. Y., & Mooney, D. J. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.06.003 · Cited by 8,095
Sapsford, K. E., Algar, W. R., Berti, L., Gemmill, K. B., Casey, B. J., Oh, E., Stewart, M. H., & Medintz, I. L. (2013) · Chemical Reviews · doi:10.1021/cr300143v · Cited by 1,423
Alginate composites for bone tissue engineering: A review
Venkatesan, J., Bhatnagar, I., Manivasagan, P., Kang, K.-H., & Kim, S.-K. (2015) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2014.07.008 · Cited by 906
Calcium phosphates in biomedical applications: materials for the future?
Habraken, W., Habibovic, P., Epple, M., & Bohner, M. (2016) · Materials Today · doi:10.1016/j.mattod.2015.10.008 · Cited by 857
Freeman, F. E., & Kelly, D. J. (2017) · Scientific Reports · doi:10.1038/s41598-017-17286-1 · Cited by 362
Metadata
- Authors
- Krebs, M. D., Salter, E., Chen, E., Sutter, K. A., & Alsberg, E.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2009-03-25
- Volume
- 92A
- Issue
- 3
- Pages
- 1131-1138
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1968752732
- Cited by
- 176
- References
- 1
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.