CoChat

Stiffness of the substrate influences the phenotype of embryonic chicken cardiac myocytes

Bajaj, Piyush, Tang, Xin, Saif, Taher A., Bashir, Rashid · 2010 · Journal of Biomedical Materials Research Part A
Cited by 106

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

We examined the effect of substrate stiffness on the beating rate, force of contraction, and cytoskeletal structure of embryonic chicken cardiac myocytes by culturing them on laminin‐coated polyacrylamide (PA) substrates. Cells cultured on PA substrates with elasticity comparable to that of the native myocardium (18 kPa) exhibited the highest beating rate during the first few days of culture. The initial beating rate of individual cells on all the substrates varied significantly but began to converge within 5 days. We also examined the focal adhesions (FAs) and cytoskeletal structure on different substrates via confocal microscopy and found a higher percentage of FAs on tissue culture (TC) plastic dishes compared with the softer PA gels. Furthermore, highly aligned sarcomeric striations were clearly visible on 18 kPa, 50 kPa, and TC dish, whereas cells on 1 kPa only showed nonaligned diffused striations. The force of contraction on these substrates was measured using a micro‐electromechanical system force sensor, which showed that the force of contraction for the cells on TC dishes (F= 71.30 ± 6.38 nN) was significantly larger than those cultured on the 18‐kPa PA gel (F= 30.16 ± 3.83 nN). This is most likely due to the formation of higher percentage of FAs on the TC dishes compared with fewer FAs on the softer gels. Our cumulative findings can have a significant impact on the design of 3D cardiac tissue engineered scaffolds. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2010.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.32951

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 106

Metadata

Authors
Bajaj, P., Tang, X., Saif, T. A., & Bashir, R.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2010-10-11
Volume
95A
Issue
4
Pages
1261-1269
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2167089398
Cited by
106
References
5
FWCI
4.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stiffness of the substrate influences the phenotype of embryonic chicken cardiac myocytes. https://app.cochat.ai/papers/10.1002/jbm.a.32951
The paper
Bajaj, P., Tang, X., Saif, T. A., & Bashir, R. (2010). Stiffness of the substrate influences the phenotype of embryonic chicken cardiac myocytes. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.32951

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.