CoChat

The administration of BDNF and GDNF to the brain via PLGA microparticles patterned within a degradable PEG‐based hydrogel: Protein distribution and the glial response

Lampe, Kyle J., Kern, Drew S., Mahoney, Melissa J., Bjugstad, Kimberly B. · 2011 · Journal of Biomedical Materials Research Part A
Cited by 98

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Tailored delivery of neurotrophic factors (NFs) is a critical challenge that continues to inhibit strategies for guidance of axonal growth in vivo. Of particular importance is the ability to recreate innervation of distant brain regions by transplant tissue, for instance rebuilding the nigrostriatal track, one focus in Parkinson's disease research. Many strategies have utilized polymer drug delivery to target NF release in space and time, but combinatorial approaches are needed to deliver multiple NFs at relevant therapeutic times and locations without toxic side effects. Here we engineered a paradigm of PLGA microparticles entrapped within a degradable PEG‐based hydrogel device to locally release two different types of NFs with two different release profiles. Hydrogel/microparticle devices were developed and analyzed for their ability to release GDNF in the caudal area of the brain, near the substantia nigra, or BDNF in the rostral area, near the striatum. The devices delivered their respective NFs in a region localized to within 100 μm of the bridge, but not exclusively to the targeted rostral or caudal ends. BDNF was slowly released over a 56‐day period, whereas a bolus of GDNF was released around 28 days. The timed delivery of NFs from implanted devices significantly reduced the microglial response relative to sham surgeries. Given the coordinated drug delivery ability and reduced localized inflammatory response, this multifaceted PEG hydrogel/PLGA microparticle strategy may be a useful tool for further development in combining tissue engineering and drug delivery, and recreating the nigrostriatal track. © 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2011.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.33011

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 98

Metadata

Authors
Lampe, K. J., Kern, D. S., Mahoney, M. J., & Bjugstad, K. B.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2011-01-14
Volume
96A
Issue
3
Pages
595-607
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2007135911
Cited by
98
References
12
FWCI
2.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.