CoChat

Local effect of IL‐4 delivery on polyethylene particle induced osteolysis in the murine calvarium

Open access
Rao, Allison J., Nich, Christophe, Dhulipala, Lakshmi S., Gibon, Emmanuel, Valladares, Roberto, Zwingenberger, Stefan, Smith, R. Lane, Goodman, Stuart B. · 2013 · Journal of Biomedical Materials Research Part A
Cited by 76

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Wear particles generated with use of total joint replacements incite a chronic macrophage‐mediated inflammatory reaction, which leads to implant failure. Macrophage activation may be polarized into two states, with an M1 proinflammatory state dominating an alternatively activated M2 anti‐inflammatory state. We hypothesized that IL‐4, an activator of M2 macrophages, could modulate polyethylene (PE) particle‐induced osteolysis in an experimental murine model. Four animal groups included (a) calvarial saline injection with harvest at 14 days (b) single calvarial injection of PE particles subcutaneously (SC) without IL‐4 (c) PE particles placed as in (b), then IL‐4 given SC for 14 consecutive days and (d) PE particles as in (b) then IL‐4 beginning 7 days after particle injection for 7 days. The calvarial bone volume to total tissue volume was measured using microCT and histomorphometry. Calvaria were cultured for 24 h to assess release of RANKL, OPG, TNF‐α, and IL‐1ra and isolation and identification of M1 and M2 specific proteins. MicroCT and histomorphometric analysis showed that bone loss was significantly decreased following IL‐4 administration to PE treated calvaria for both 7 and 14 days. Western blot analysis showed an increased M1/M2 ratio in the PE treated calvaria, which decreased with addition of IL‐4. Cytokine analysis showed that the RANKL/OPG ratio and TNF‐α/IL‐1ra ratio decreased in PE‐treated calvaria following IL‐4 addition for 14 days. IL‐4 delivery mitigated PE particle‐induced osteolysis through macrophage polarization. Modulation of macrophage polarization is a potential treatment strategy for wear particle induced periprosthetic osteolysis. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2013.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.34486

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 76

Metadata

Authors
Rao, A. J., Nich, C., Dhulipala, L. S., Gibon, E., Valladares, R., Zwingenberger, S., Smith, R. L., & Goodman, S. B.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2012-12-05
Volume
101A
Issue
7
Pages
1926-1934
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2072233830
Cited by
76
References
4
FWCI
8.12
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.