The recognition of biomaterials: Pattern recognition of medical polymers and their adsorbed biomolecules
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
All biomedical materials are recognized as foreign entities by the host immune system despite the substantial range of different materials that have been developed by material scientists and engineers. Hydrophobic biomaterials, hydrogels, biomaterials with low protein binding surfaces, and those that readily adsorb a protein layer all seem to incite similar host responses in vivo that may differ in magnitude, but ultimately result in encapsulation by fibrotic tissue. The recognition of medical materials by the host is explained by the very intricate pattern recognition system made up of integrins, toll‐like receptors, scavenger receptors, and other surface proteins that enable leukocytes to perceive almost any foreign body. In this review, we describe the various pattern recognition receptors and processes that occur on biomedical material surfaces that permit detection of a range of materials within the host. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 101A: 2740–2752, 2013.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1×
“Therefore, it is accepted that elements of this initial protein coat mediate the response.(5,6) Fibrinogen (Fg), albumin, and immunoglobulin (Ig) are the most abundant proteins in plasma, and typically dominate on the material surface upon implantation.”
Mediation of biomaterial-cell interactions by adsorbed proteins: a review
Wilson, C. J., Clegg, R. E., Leavesley, D. I., & Pearcy, M. J. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1 · Cited by 1,696
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465 · cited 1×
“By the time most of the monocytes reach the implantation site, the inflammatory response is fully underway.(75) As a result, monocytes are mostly activated by the inflammatory mediators in the local milieu.”
Oligosaccharides of Hyaluronan Activate Dendritic Cells via Toll-like Receptor 4
Termeer, C., Benedix, F., Sleeman, J., Fieber, C., Voith, U., Ahrens, T., Miyake, K., Freudenberg, M., Galanos, C., & Simon, J. C. (2002) · The Journal of Experimental Medicine · doi:10.1084/jem.20001858 · Cited by 1,378
mRNA is an endogenous ligand for toll-like receptor 3
Karikó, K., Ni, H., Capodici, J., Lamphier, M., & Weissman, D. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m310175200 · Cited by 1,062
Keselowsky, B. G., Collard, D. M., & García, A. J. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10537 · Cited by 949
Schaefer, L., Babelova, A., Kiss, E., Hausser, H.-J., Baliova, M., Krzyzankova, M., Marsche, G., Young, M. F., Mihalik, D., Götte, M., et al. (2005) · Journal of Clinical Investigation · doi:10.1172/jci23755 · Cited by 850
HMGB1 SIGNALS THROUGH TOLL-LIKE RECEPTOR (TLR) 4 AND TLR2
Yu, M., Wang, H., Ding, A., Golenbock, D. T., Latz, E., Czura, C. J., Fenton, M. J., Tracey, K. J., & Yang, H. (2006) · Shock · doi:10.1097/01.shk.0000225404.51320.82 · Cited by 832
Interaction of high molecular weight kininogen, factor XII, and fibrinogen in plasma at interfaces
Vroman, L., Adams, A., Fischer, G., & Munoz, P. (1980) · Blood · doi:10.1182/blood.v55.1.156.156 · Cited by 781
Hyaluronan Fragments Act as an Endogenous Danger Signal by Engaging TLR2
Scheibner, K. A., Lutz, M. A., Boodoo, S., Fenton, M. J., Powell, J. D., & Horton, M. R. (2006) · The Journal of Immunology · doi:10.4049/jimmunol.177.2.1272 · Cited by 708
Cited by
The pathology of the foreign body reaction against biomaterials
Klopfleisch, R., & Jung, F. (2017) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35958 · Cited by 524
Implant Fibrosis and the Underappreciated Role of Myofibroblasts in the Foreign Body Reaction
Noskovicova, N., Hinz, B., & Pakshir, P. (2021) · Cells · doi:10.3390/cells10071794 · Cited by 184
Biomaterials-Driven Sterile Inflammation
Chen, H., Agrawal, D. K., & Thankam, F. G. (2022) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2020.0253 · Cited by 41
Metadata
- Authors
- Love, R. J., & Jones, K. S.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2013-07-30
- Volume
- 101A
- Issue
- 9
- Pages
- 2740-2752
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1597534975
- Cited by
- 38
- References
- 22
- FWCI
- 1.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The recognition of biomaterials: Pattern recognition of medical polymers and their adsorbed biomolecules. https://app.cochat.ai/papers/10.1002/jbm.a.34577
- The paper
- Love, R. J., & Jones, K. S. (2013). The recognition of biomaterials: Pattern recognition of medical polymers and their adsorbed biomolecules. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.34577
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.