A review of integrating electroactive polymers as responsive systems for specialized drug delivery applications
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Electroactive polymers (EAPs) are promising candidate materials for the design of drug delivery technologies, especially in conditions where an “on–off” drug release mechanism is required. To achieve this, EAPs such as polyaniline, polypyrrole, polythiophene, ethylene vinyl acetate, and polyethylene may be blended into responsive hydrogels in conjunction with the desired drug to obtain a patient‐controlled drug release system. The “on–off” drug release mechanism can be achieved through the environmental‐responsive nature of the interpenetrating hydrogel‐EAP complex via (i) charged ions initiated diffusion of drug molecules; (ii) conformational changes that occur during redox switching of EAPs; or (iii) electroerosion. These release mechanisms are not exhaustive and new release mechanisms are still under investigation. Therefore, this review seeks to provide a concise incursion and critical overview of EAPs and responsive hydrogels as a strategy for advanced drug delivery, for example, controlled release of neurotransmitters, sulfosalicyclic acid from cross‐linked hydrogel, and vaccine delivery. The review further discusses techniques such as linear sweep voltammetry, cyclic voltammetry, impedance spectroscopy, and chronoamperometry for the determination of the redox capability of EAPs. The future implications of the hydrogel‐EAP composites include, but not limited to, application toward biosensors, DNA hybridizations, microsurgical tools, and miniature bioreactors and may be utilized to their full potential in the form of injectable devices as nanorobots or nanobiosensors. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 2039–2054, 2014.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels for biomedical applications
Hoffman, A. S. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00239-3 · Cited by 4,864
Cited by
Engineered Nanoparticles for Drug Delivery in Cancer Therapy
Sun, T., Zhang, Y. S., Pang, B., Hyun, D. C., Yang, M., & Xia, Y. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201403036 · Cited by 2,164
Qu, J., Zhao, X., Ma, P. X., & Guo, B. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.03.018 · Cited by 468
Feiner, R., Engel, L., Fleischer, S., Malki, M., Gal, I., Shapira, A., Shacham-Diamand, Y., & Dvir, T. (2016) · Nature Materials · doi:10.1038/nmat4590 · Cited by 460
External triggering and triggered targeting strategies for drug delivery
Wang, Y., & Kohane, D. S. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.20 · Cited by 418
Stimuli-Responsive Drug Release from Smart Polymers
Wells, C. M., Harris, M., Choi, L., Murali, V. P., Guerra, F. D., & Jennings, J. A. (2019) · Journal of Functional Biomaterials · doi:10.3390/jfb10030034 · Cited by 341
Metadata
- Authors
- Pillay, V., Tsai, T., Choonara, Y. E., du Toit, L. C., Kumar, P., Modi, G., Naidoo, D., Tomar, L. K., Tyagi, C., & Ndesendo, V. M. K.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2013-07-30
- Volume
- 102
- Issue
- 6
- Pages
- 2039-2054
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2112439708
- Cited by
- 114
- References
- 1
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.