CoChat

A review of integrating electroactive polymers as responsive systems for specialized drug delivery applications

Pillay, Viness, Tsai, Tong‐Sheng, Choonara, Yahya E., du Toit, Lisa C., Kumar, Pradeep, Modi, Girish, Naidoo, Dinesh, Tomar, Lomas K., Tyagi, Charu, Ndesendo, Valence M. K. · 2014 · Journal of Biomedical Materials Research Part A
Cited by 114

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Electroactive polymers (EAPs) are promising candidate materials for the design of drug delivery technologies, especially in conditions where an “on–off” drug release mechanism is required. To achieve this, EAPs such as polyaniline, polypyrrole, polythiophene, ethylene vinyl acetate, and polyethylene may be blended into responsive hydrogels in conjunction with the desired drug to obtain a patient‐controlled drug release system. The “on–off” drug release mechanism can be achieved through the environmental‐responsive nature of the interpenetrating hydrogel‐EAP complex via (i) charged ions initiated diffusion of drug molecules; (ii) conformational changes that occur during redox switching of EAPs; or (iii) electroerosion. These release mechanisms are not exhaustive and new release mechanisms are still under investigation. Therefore, this review seeks to provide a concise incursion and critical overview of EAPs and responsive hydrogels as a strategy for advanced drug delivery, for example, controlled release of neurotransmitters, sulfosalicyclic acid from cross‐linked hydrogel, and vaccine delivery. The review further discusses techniques such as linear sweep voltammetry, cyclic voltammetry, impedance spectroscopy, and chronoamperometry for the determination of the redox capability of EAPs. The future implications of the hydrogel‐EAP composites include, but not limited to, application toward biosensors, DNA hybridizations, microsurgical tools, and miniature bioreactors and may be utilized to their full potential in the form of injectable devices as nanorobots or nanobiosensors. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 2039–2054, 2014.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.34869

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Pillay, V., Tsai, T., Choonara, Y. E., du Toit, L. C., Kumar, P., Modi, G., Naidoo, D., Tomar, L. K., Tyagi, C., & Ndesendo, V. M. K.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2013-07-30
Volume
102
Issue
6
Pages
2039-2054
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2112439708
Cited by
114
References
1
FWCI
4.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.