The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
The langmuir isotherm: A commonly applied but misleading approach for the analysis of protein adsorption behavior
Abstract
The Langmuir adsorption isotherm provides one of the simplest and most direct methods to quantify an adsorption process. Because isotherm data from protein adsorption studies often appear to be fit well by the Langmuir isotherm model, estimates of protein binding affinity have often been made from its use despite that fact that none of the conditions required for a Langmuir adsorption process may be satisfied for this type of application. The physical events that cause protein adsorption isotherms to often provide a Langmuir‐shaped isotherm can be explained as being due to changes in adsorption‐induced spreading, reorientation, clustering, and aggregation of the protein on a surface as a function of solution concentration in contrast to being due to a dynamic equilibrium adsorption process, which is required for Langmuir adsorption. Unless the requirements of the Langmuir adsorption process can be confirmed, fitting of the Langmuir model to protein adsorption isotherm data to obtain thermodynamic properties, such as the equilibrium constant for adsorption and adsorption free energy, may provide erroneous values that have little to do with the actual protein adsorption process, and should be avoided. In this article, a detailed analysis of the Langmuir isotherm model is presented along with a quantitative analysis of the level of error that can arise in derived parameters when the Langmuir isotherm is inappropriately applied to characterize a protein adsorption process. © 2014 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 103A: 949–958, 2015.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adsorption of Gases in Multimolecular Layers
Brunauer, S., Emmett, P. H., & Teller, E. (1938) · Journal of the American Chemical Society · doi:10.1021/ja01269a023 · Cited by 28,156
THE CONSTITUTION AND FUNDAMENTAL PROPERTIES OF SOLIDS AND LIQUIDS. PART I. SOLIDS.
Langmuir, I. (1916) · Journal of the American Chemical Society · doi:10.1021/ja02268a002 · Cited by 9,997
Insights into the modeling of adsorption isotherm systems
Foo, K. Y., & Hameed, B. H. (2010) · Chemical Engineering Journal · doi:10.1016/j.cej.2009.09.013 · Cited by 8,479
Sorption isotherms: A review on physical bases, modeling and measurement
Limousin, G., Gaudet, J.-P., Charlet, L., Szenknect, S., Barthès, V., & Krimissa, M. (2007) · Applied Geochemistry · doi:10.1016/j.apgeochem.2006.09.010 · Cited by 1,724
Understanding protein adsorption phenomena at solid surfaces
Rabe, M., Verdes, D., & Seeger, S. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2010.12.007 · Cited by 1,664
On the adsorption of proteins on solid surfaces, a common but very complicated phenomenon
Nakanishi, K., Sakiyama, T., & Imamura, K. (2001) · Journal of Bioscience and Bioengineering · doi:10.1016/s1389-1723(01)80127-4 · Cited by 1,006
Globular proteins at solid/liquid interfaces
Haynes, C. A., & Norde, W. (1994) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/0927-7765(94)80066-9 · Cited by 852
Proteins at Interfaces II: Fundamentals and Applications
(1995) · ACS Symposium Series · doi:10.1021/bk-1995-0602 · Cited by 555
Vroman, L., & Adams, A. L. (1969) · Surface Science · doi:10.1016/0039-6028(69)90037-5 · Cited by 368
Wertz, C. F., & Santore, M. M. (2001) · Langmuir · doi:10.1021/la0017781 · Cited by 363
My voyage of discovery to proteins in flatland … and beyond
Norde, W. (2008) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2007.09.029 · Cited by 326
Proteins at Interfaces: Physicochemical and Biochemical Studies
(1987) · ACS Symposium Series · doi:10.1021/bk-1987-0343 · Cited by 267
Wertz, C. F., & Santore, M. M. (1999) · Langmuir · doi:10.1021/la990089q · Cited by 230
Review of new experimental techniques for investigating random sequential adsorption
Ramsden, J. J. (1993) · Journal of Statistical Physics · doi:10.1007/bf01052813 · Cited by 219
Puzzles and paradoxes in protein adsorption
Ramsden, J. J. (1995) · Chemical Society Reviews · doi:10.1039/cs9952400073 · Cited by 180
Control of Protein Adsorption: Molecular Level Structural and Spatial Variables
Vanderah, D. J., La, H., Naff, J., Silin, V. I., & Rubinson, K. A. (2004) · Journal of the American Chemical Society · doi:10.1021/ja047744n · Cited by 119
(2003) · Routledge eBooks · doi:10.4324/9780203912003 · Cited by 110
Slack, S. M., & Horbett, T. A. (1995) · ACS symposium series · doi:10.1021/bk-1995-0602.ch008 · Cited by 91
Thermodynamics of Enzyme-Catalyzed Reactions: Part 1. Oxidoreductases
Goldberg, R. N., Tewari, Y. B., Bell, D., Fazio, K., & Anderson, E. (1993) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555939 · Cited by 69
Time-Dependent Conformational Changes in Adsorbed Albumin and Its Effect on Platelet Adhesion
Balakrishnan, S., & Latour, R. A. (2011) · Langmuir · doi:10.1021/la204777x · Cited by 65
Self-citationStandard States for Adsorption on Solid Surfaces: 2D Gases, Surface Liquids, and Langmuir Adsorbates
Savara, A. (2013) · The Journal of Physical Chemistry C · doi:10.1021/jp404398z · Cited by 58
Thermodynamics of Enzyme-Catalyzed Reactions: Part 2. Transferases
Goldberg, R. N., & Tewari, Y. B. (1994) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555948 · Cited by 43
Cited by
Li, Q., Wen, C., Yang, J., Zhou, X., Zhu, Y., Zheng, J., Cheng, G., Bai, J., Xu, T., Ji, J., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00344 · Cited by 790
Optimizing the utilization of aluminum adjuvants in vaccines: you might just get what you want
HogenEsch, H., O’Hagan, D. T., & Fox, C. B. (2018) · npj Vaccines · doi:10.1038/s41541-018-0089-x · Cited by 391
Kirkwood, N., Monchen, J. O. V., Crisp, R. W., Grimaldi, G., Bergstein, H. A. C., du Fossé, I., van der Stam, W., Infante, I., & Houtepen, A. J. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b07783 · Cited by 299
Nonspecific Binding—Fundamental Concepts and Consequences for Biosensing Applications
Frutiger, A., Tanno, A., Hwu, S., Tiefenauer, R. F., Vörös, J., & Nakatsuka, N. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00044 · Cited by 278
Gao, N., Zhou, W., Jiang, X., Hong, G., Fu, T.-M., & Lieber, C. M. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b00133 · Cited by 268
Metadata
- Authors
- Latour, R. A.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2014-06-03
- Volume
- 103
- Issue
- 3
- Pages
- 949-958
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1529813175
- Cited by
- 296
- References
- 22
- FWCI
- 3.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.