In vitro response of MC3T3‐E1 preosteoblasts within three‐dimensional apatite‐coated PLGA scaffolds
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Biomimetic apatites have been reported to promote osteogenic activities in numerous in vivo and in vitro models, but the precise mechanism by which the apatite microenvironment promotes such activities is not well understood. Such mechanistic studies require reproducible model systems that are relevant to tissue engineering practices. Although two‐dimensional (2D) apatite‐coated polystyrene culture dishes provide practicality and reproducibility, they do not simulate the effects of the three‐dimensional (3D) microenvironment and degrading polymeric substrates. A simple 3D model system to address these relevant effects, and its utilization in the investigation of apatite‐promoted osteoblastic differentiation in vitro is reported in this paper. Apatite coating was achieved by sequentially immersing poly(lactide‐co‐glycolide) (PLGA) scaffolds into different simulated body fluids (SBF). SEM, EDX, FTIR, TEM electron diffraction confirmed the apatite coating to comprise of calcium‐deficient carbonated hydroxyapatite crystals. While both apatite‐coated and noncoated PLGA scaffolds supported MC3T3‐E1 attachment, spreading, and proliferation, significant differences in osteoblastic differentiation were observed. Relative to noncoated controls, quantitative real‐time PCR revealed significant apatite‐associated suppression of alkaline phosphatase (ALP), early upregulation of osteopontin (OPN) at 3 days, and upregulation of osteocalcin (OCN) and bone sialoprotein (BSP) at 4 weeks. In summary, apatite‐promoted osteoblastic differentiation can be observed in a 3D model system that is relevant to tissue engineering. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Taking Cell-Matrix Adhesions to the Third Dimension
Cukierman, E., Pankov, R., Stevens, D. R., & Yamada, K. M. (2001) · Science · doi:10.1126/science.1064829 · Cited by 3,027 · cited 1×
“Besides adhesion receptors, major differences in adhesion-mediated signal transduction and structural organization of cell adhesion components have been described between 2D and 3D substrates.(11,12)”
BackgroundThe effect of scaffold degradation rate on three-dimensional cell growth and angiogenesis
Sung, H.-J., Meredith, C., Johnson, C., & Galis, Z. S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.066 · Cited by 804 · cited 1×
“It has been reported that the degradation of PLGA scaffolds results in the decrease of environmental pH which further affects cell viability after 28 days culture.(9) Even if such degradation effects are negligible, it is not known if effects observed in 2D model systems can be generalized to 3D microenvironments whic…”
Background
Cited by
Polymeric materials for bone and cartilage repair
Puppi, D., Chiellini, F., Piras, A. M., & Chiellini, E. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.01.006 · Cited by 913
Synthetic biodegradable functional polymers for tissue engineering: a brief review
Guo, B., & Ma, P. X. (2014) · Science China Chemistry · doi:10.1007/s11426-014-5086-y · Cited by 592
Zara, J. N., Siu, R. K., Zhang, X., Shen, J., Ngo, R., Lee, M., Li, W., Chiang, M., Chung, J., Kwak, J., et al. (2011) · Tissue Engineering Part A · doi:10.1089/ten.tea.2010.0555 · Cited by 560
Self-citationMesenchymal stem cell ingrowth and differentiation on coralline hydroxyapatite scaffolds
Mygind, T., Stiehler, M., Baatrup, A., Li, H., Zou, X., Flyvbjerg, A., Kassem, M., & Bünger, C. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.10.003 · Cited by 378
Ngiam, M., Liao, S., Patil, A. J., Cheng, Z., Chan, C. K., & Ramakrishna, S. (2009) · Bone · doi:10.1016/j.bone.2009.03.674 · Cited by 341
Metadata
- Authors
- Chou, Y., Dunn, J. C. Y., & Wu, B. M.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2005-07-06
- Volume
- 75B
- Issue
- 1
- Pages
- 81-90
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2115051957
- Cited by
- 118
- References
- 2
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vitro response of MC3T3‐E1 preosteoblasts within three‐dimensional apatite‐coated PLGA scaffolds. https://app.cochat.ai/papers/10.1002/jbm.b.30261
- The paper
- Chou, Y., Dunn, J. C. Y., & Wu, B. M. (2005). In vitro response of MC3T3‐E1 preosteoblasts within three‐dimensional apatite‐coated PLGA scaffolds. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.30261
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.