Repair of the dura mater with processed collagen devices
The DOI matches its Crossref record.
Abstract
Background: We evaluated in a canine duraplasty model how specific differences in device physicomechanical properties, porosity, and crosslinking influenced the biological performance of three processed collagen dural substitutes. Methods: Three collagen dural substitutes were studied: Dura‐Guard, DuraGen, and Durepair. The initial strength, stiffness, and suture retention force were measured using standard mechanical test methods. The relative pore sizes of each device were assessed with a scanning electron microscope. Differential scanning calorimetry was used to measure their respective collagen denaturation temperatures. The biologic response and performance of the materials were evaluated via an acute (1 month) and long‐term (3 and 6 months) canine bilateral duraplasty study. Results: The mechanical properties of Dura‐Guard and Durepair were similar to native dura. We could not quantify the mechanical properties of DuraGen because of its fragile nature. The denaturation temperature of DuraGen and Dura‐Guard differed significantly from that reported for native collagens. The denaturation temperature of Durepair was comparable with the values reported for native collagens. All three materials were tolerated well by the animals. DuraGen did not maintain its structural integrity beyond 1 month. Dura‐Guard and Durepair persisted for 6 months. Durepair was populated by fibroblasts and blood vessels, whereas Dura‐Guard was not. Conclusions: The three dural substitutes tested were found to be safe and effective in healing surgically created defects in the dura mater. Although each of these dura substitutes are composed of collagen, differences in the collagen source and processing influenced device physicomechanical properties, porosity, and the nativity of the collagen polymer. These measured differences influenced device intraoperative handling and installation as well as the post‐operative biological response, where differences in device resorption, cell penetration, vascularization, and collagen remodeling were observed. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2007
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Processing of collagen based biomaterials and the resulting materials properties
Meyer, M. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0647-0 · Cited by 539
Xie, J., MacEwan, M. R., Ray, W. Z., Liu, W., Siewe, D. Y., & Xia, Y. (2010) · ACS Nano · doi:10.1021/nn101554u · Cited by 315
The effect of source animal age upon extracellular matrix scaffold properties
Tottey, S., Johnson, S. A., Crapo, P. M., Reing, J. E., Zhang, L., Jiang, H., Medberry, C. J., Reines, B., & Badylak, S. F. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.006 · Cited by 138
“fetal wound healing results in less scar tissue formation and a more regenerative outcome than the adult response to tissue injury [23e25] and for this reason some biologic scaffolds use source materials that include fetal or neonatal cells [26,27], or fetal ECM [28].”
Metadata
- Authors
- Zerris, V. A., James, K. S., Roberts, J. B., Bell, E., & Heilman, C. B.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2007-04-26
- Volume
- 83B
- Issue
- 2
- Pages
- 580-588
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2050014023
- Cited by
- 127
- References
- 0
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Repair of the dura mater with processed collagen devices. https://app.cochat.ai/papers/10.1002/jbm.b.30831
- The paper
- Zerris, V. A., James, K. S., Roberts, J. B., Bell, E., & Heilman, C. B. (2007). Repair of the dura mater with processed collagen devices. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.30831
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.