The DOI matches its Crossref record.
Physically crosslinked composite hydrogels of PVA with natural macromolecules: Structure, mechanical properties, and endothelial cell compatibility
Abstract
Polyvinyl alcohol (PVA) hydrogels have been considered potentially suitable for applications as engineered blood vessels because of their structure and mechanical properties. However, PVA's hydrophilicity hinders its capacity to act as a substrate for cell attachment. As a remedy, PVA was blended with chitosan, gelatin, or starch, and hydrogels were formed by subjecting the solutions to freeze‐thaw cycles followed by coagulation bath immersion. The structure‐property relationships for these hydrogels were examined by measurement of their swelling, rehydration, degradation, and mechanical properties. For the case of pure PVA hydrogels, the equilibrium swelling ratio was used to predict the effect of freeze thaw cycles and coagulation bath on average molecular weights between crosslinks and on mesh size. For all hydrogels, trends for the reswelling ratio, which is indicative of the crosslinked polymer fraction, were consistent with relative tensile properties. The coagulation bath treatment increased the degradation resistance of the hydrogels significantly. The suitability of each hydrogel for cell attachment and proliferation was examined by protein adsorption and bovine vascular endothelial cell culture experiments. Protein adsorption and cell proliferation was highest on the PVA/gelatin hydrogels. This study demonstrates that the potential of PVA hydrogels for artificial blood vessel applications can be improved by the addition of natural polymers, and that freeze‐thawing and coagulation bath treatment can be utilized for fine adjustment of the physical characteristics. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A mini review on hydrogels classification and recent developments in miscellaneous applications
Varaprasad, K., Raghavendra, G. M., Jayaramudu, T., Yallapu, M. M., & Sadiku, R. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.05.096 · Cited by 534
Cryogels for biomedical applications
Henderson, T. M. A., Ladewig, K., Haylock, D. N., McLean, K. M., & O'Connor, A. J. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20280a · Cited by 296
Biomedical applications of hydrogels in drug delivery system: An update
Kesharwani, P., Bisht, A., Alexander, A., Dave, V., & Sharma, S. (2021) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2021.102914 · Cited by 288
A Hydrogel Microneedle Patch for Point‐of‐Care Testing Based on Skin Interstitial Fluid
He, R., Niu, Y., Li, Z., Li, A., Yang, H., Xu, F., & Li, F. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901201 · Cited by 257
Fu, P.-S., Wang, J.-C., Lai, P.-L., Liu, S.-M., Chen, Y.-S., Chen, W.-C., & Hung, C.-C. (2021) · Polymers · doi:10.3390/polym13060938 · Cited by 25
Metadata
- Authors
- Liu, Y., Vrana, N. E., Cahill, P. A., & McGuinness, G. B.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2009-01-14
- Volume
- 90B
- Issue
- 2
- Pages
- 492-502
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W1993695382
- Cited by
- 206
- References
- 0
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physically crosslinked composite hydrogels of PVA with natural macromolecules: Structure, mechanical properties, and endothelial cell compatibility. https://app.cochat.ai/papers/10.1002/jbm.b.31310
- The paper
- Liu, Y., Vrana, N. E., Cahill, P. A., & McGuinness, G. B. (2009). Physically crosslinked composite hydrogels of PVA with natural macromolecules: Structure, mechanical properties, and endothelial cell compatibility. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.31310
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.