The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
A Hydrogel Microneedle Patch for Point‐of‐Care Testing Based on Skin Interstitial Fluid
Abstract
Skin interstitial fluid (ISF) holds great potential as a highly desirable sample resource for point‐of‐care testing (POCT), where the key is to effectively collect target biomarkers from ISF. Hydrogel microneedle patch has great promise for ISF extraction. However, it is challenging to recover target biomarkers from the extracted skin ISF in hydrogel microneedle patches in an easy‐administrated, fast, and bulky instrument‐free manner. Herein, a hydrogel microneedle patch made of polyvinyl alcohol (PVA) and chitosan (CS) for POCT based on the ISF is developed. The phase transition property of PVA/CS hydrogel makes the microneedles stiff when dry, which is beneficial to easily penetrate into skin. Meanwhile, the highly porous microstructure of hydrogel offers good swelling ability for extraction of ISF and the thermal degradation property of PVA makes it convenient to quickly and efficiently recover target biomarkers from microneedle patch. The capability of this platform for POCT applications is further demonstrated by successful detections of typical biomarkers collected from the mimetic skin and monitoring the glucose level in rabbit skins during a day. The developed hydrogel microneedle patch holds the advantages of extraction of skin ISF and recovery of biomarkers, thus presenting as a powerful platform for skin ISF‐based POCT applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Hassan, C. M., & Peppas, N. A. (2007) · Advances in Polymer Science · doi:10.1007/3-540-46414-x_2 · Cited by 1,356
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Gyles, D. A., Castro, L. D., Silva, J. O. C., & Ribeiro-Costa, R. M. (2017) · European Polymer Journal · doi:10.1016/j.eurpolymj.2017.01.027 · Cited by 527
Rapidly separable microneedle patch for the sustained release of a contraceptive
Li, W., Terry, R. N., Tang, J., Feng, M. R., Schwendeman, S. P., & Prausnitz, M. R. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0337-4 · Cited by 492
Chang, H., Zheng, M., Yu, X., Than, A., Seeni, R. Z., Kang, R., Tian, J., Khanh, D. P., Liu, L., Chen, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702243 · Cited by 462
Yokoyama, F., Masada, I., Shimamura, K., Ikawa, T., & Monobe, K. (1986) · Colloid & Polymer Science · doi:10.1007/bf01412597 · Cited by 375
Lipani, L., Dupont, B. G. R., Doungmene, F., Marken, F., Tyrrell, R. M., Guy, R. H., & Ilie, A. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0112-4 · Cited by 340
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Antifouling Strategies for Selective In Vitro and In Vivo Sensing
Jiang, C., Wang, G., Hein, R., Liu, N., Luo, X., & Davis, J. J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00739 · Cited by 598
Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid
Wang, Z., Luan, J., Seth, A., Liu, L., You, M., Gupta, P., Rathi, P., Wang, Y., Cao, S., Jiang, Q., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00672-y · Cited by 386
Chitosan-based microneedle arrays for dermal delivery of Centella asiatica
Ryall, C., Chen, S., Duarah, S., & Wen, J. (2022) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2022.122221 · Cited by 65
Microneedles: A novel clinical technology for evaluating skin characteristics
Kim, S. H., Kim, J. H., Choi, Y. M., Seo, S. M., Jang, E. Y., Lee, S. J., Cho, S., Jeong, D. H., & Lee, K. H. (2024) · Skin Research and Technology · doi:10.1111/srt.13647 · Cited by 10
Metadata
- Authors
- He, R., Niu, Y., Li, Z., Li, A., Yang, H., Xu, F., & Li, F.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2020-01-20
- Volume
- 9
- Issue
- 4
- Pages
- e1901201-e1901201
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W3001424928
- Cited by
- 257
- References
- 39
- FWCI
- 10.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Hydrogel Microneedle Patch for Point‐of‐Care Testing Based on Skin Interstitial Fluid. https://app.cochat.ai/papers/10.1002/adhm.201901201
- The paper
- He, R., Niu, Y., Li, Z., Li, A., Yang, H., Xu, F., & Li, F. (2020). A Hydrogel Microneedle Patch for Point‐of‐Care Testing Based on Skin Interstitial Fluid. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201901201
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.