The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A simplified in vivo approach for evaluating the bioabsorbable behavior of candidate stent materials
Abstract
Metal stents are commonly used to revascularize occluded arteries. A bioabsorbable metal stent that harmlessly erodes away over time may minimize the normal chronic risks associated with permanent implants. However, there is no simple, low‐cost method of introducing candidate materials into the arterial environment. Here, we developed a novel experimental model where a biomaterial wire is implanted into a rat artery lumen (simulating bioabsorbable stent blood contact) or artery wall (simulating bioabsorbable stent matrix contact). We use this model to clarify the corrosion mechanism of iron (≥99.5 wt %), which is a candidate bioabsorbable stent material due to its biocompatibility and mechanical strength. We found that iron wire encapsulation within the arterial wall extracellular matrix resulted in substantial biocorrosion by 22 days, with a voluminous corrosion product retained within the vessel wall at 9 months. In contrast, the blood‐contacting luminal implant experienced minimal biocorrosion at 9 months. The importance of arterial blood versus arterial wall contact for regulating biocorrosion was confirmed with magnesium wires. We found that magnesium was highly corroded when placed in the arterial wall but was not corroded when exposed to blood in the arterial lumen for 3 weeks. The results demonstrate the capability of the vascular implantation model to conduct rapid in vivo assessments of vascular biomaterial corrosion behavior and to predict long‐term biocorrosion behavior from material analyses. The results also highlight the critical role of the arterial environment (blood vs. matrix contact) in directing the corrosion behavior of biodegradable metals. © 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2012.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Recent advances on the development of magnesium alloys for biodegradable implants
Chen, Y., Xu, Z., Smith, C., & Sankar, J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.005 · Cited by 1,236
Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stents
Bowen, P. K., Drelich, J., & Goldman, J. (2013) · Advanced Materials · doi:10.1002/adma.201300226 · Cited by 928
Self-citationZinc-based alloys for degradable vascular stent applications
Mostaed, E., Sikora-Jasinska, M., Drelich, J. W., & Vedani, M. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.03.005 · Cited by 565
Self-citationBiodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn‐Alloys
Bowen, P. K., Shearier, E. R., Zhao, S., Guillory, R. J., Zhao, F., Goldman, J., & Drelich, J. W. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201501019 · Cited by 544
Self-citation
Metadata
- Authors
- Pierson, D., Edick, J., Tauscher, A., Pokorney, E., Bowen, P., Gelbaugh, J., Stinson, J., Getty, H., Lee, C. H., Drelich, J., & Goldman, J.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2011-09-08
- Volume
- 100B
- Issue
- 1
- Pages
- 58-67
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2019385746
- Cited by
- 195
- References
- 1
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A simplified in vivo approach for evaluating the bioabsorbable behavior of candidate stent materials. https://app.cochat.ai/papers/10.1002/jbm.b.31922
- The paper
- Pierson, D., Edick, J., Tauscher, A., Pokorney, E., Bowen, P., Gelbaugh, J., Stinson, J., Getty, H., Lee, C. H., Drelich, J., & Goldman, J. (2012). A simplified in vivo approach for evaluating the bioabsorbable behavior of candidate stent materials. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.31922
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.