Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 256

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Effects of denosumab on bone turnover markers in postmenopausal osteoporosis

Open access
Eastell, Richard, Christiansen, Claus, Grauer, Andreas, Kutilek, Stepan, Libanati, Cesar, McClung, Michael R, Reid, Ian R, Resch, Heinrich, Siris, Ethel, Uebelhart, Daniel, Wang, Andrea, Weryha, Georges, Cummings, Steve R · 2011 · Journal of Bone and Mineral Research

Abstract

Denosumab, a fully human monoclonal antibody to RANKL, decreases bone remodeling, increases bone density, and reduces fracture risk. This study evaluates the time course and determinants of bone turnover marker (BTM) response during denosumab treatment, the percentage of denosumab-treated women with BTMs below the premenopausal reference interval, and the correlations between changes in BTMs and bone mineral density (BMD). The BTM substudy of the Fracture REduction Evaulation of Denosumab in Osteoporosis every 6 Months (FREEDOM) Trial included 160 women randomized to subcutaneous denosumab (60 mg) or placebo injections every 6 months for 3 years. Biochemical markers of bone resorption (serum C-telopeptide of type I collagen [CTX] and tartrate-resistant acid phosphatise [TRACP-5b]) and bone formation (serum procollagen type I N-terminal propeptide [PINP] and bone alkaline phosphatase [BALP]) were measured at baseline and at 1, 6, 12, 24, and 36 months. Decreases in CTX were more rapid and greater than decreases in PINP and BALP. One month after injection, CTX levels in all denosumab-treated subjects decreased to levels below the premenopausal reference interval. CTX values at the end of the dosing period were influenced by baseline CTX values and the dosing interval. The percentage of subjects with CTX below the premenopausal reference interval before each subsequent injection decreased from 79% to 51% during the study. CTX and PINP remained below the premenopausal reference interval at all time points in 46% and 31% denosumab-treated subjects, respectively. With denosumab, but not placebo, there were significant correlations between CTX reduction and BMD increase (r = −0.24 to −0.44). The BTM response pattern with denosumab is unique and should be appreciated by physicians to monitor this treatment effectively. © 2011 American Society for Bone and Mineral Research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbmr.251

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 256

Metadata

Authors
Eastell, R., Christiansen, C., Grauer, A., Kutilek, S., Libanati, C., McClung, M. R., Reid, I. R., Resch, H., Siris, E., Uebelhart, D., Wang, A., Weryha, G., & Cummings, S. R.
Venue
Journal of Bone and Mineral Research
Published
2010-09-13
Volume
26
Issue
3
Pages
530-537
ISSN
  • 0884-0431 (ISSN-L)
  • 1523-4681
OpenAlex
W2122467899
Cited by
256
References
19
FWCI
15.82
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.