The DOI matches its Crossref record.
In vivo, three-dimensional microscopy of trabecular bone
Abstract
Osteoporosis, which is correlated with low bone mass and increased bone fragility, is responsible for about 1.2 million fractures per year in the United States. We have used the three-dimensional (3-D), X-ray tomographic microscope to image the trabecular bone architecture of the proximal tibias of six Sprague—Dawley rats in vivo. Three of these rats were then ovariectomized to induce estrogen depletion, and three remained as controls. Five weeks later, the tibias were reimaged. The ovariectomized rats lost approximately 65% of their trabecular bone volume as compared with an insignificant change in the control rats. The connectivity density of the trabecular bone, as measured by the Euler characteristic, was linearly correlated with trabecular bone volume, even in the ovariectomized rats. Hypoestrogenemic bone loss manifested itself in greatly reduced connectivity and fewer trabecular elements, but not in thinning of trabeculae. The ability to microscopically image sequential changes in the 3-D architecture of trabecular bone in vivo will allow exploration of the earliest stages of hypoestrogenemic bone loss and to more rapidly test the effectiveness of new clinical treatments for this major public health problem.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Müller, R., Van Campenhout, H., Van Damme, B., Van der Perre, G., Dequeker, J., Hildebrand, T., & Rüegsegger, P. (1998) · Bone · doi:10.1016/s8756-3282(98)00068-4 · Cited by 656
Kraus, T., Fischerauer, S. F., Hänzi, A. C., Uggowitzer, P. J., Löffler, J. F., & Weinberg, A. M. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.11.008 · Cited by 629
X-ray microtomography of materials
Stock, S. R. (1999) · International Materials Reviews · doi:10.1179/095066099101528261 · Cited by 366
Metadata
- Authors
- Dr. Kinney, J. H., Lane, N. E., & Haupt, D. L.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1995-02-01
- Volume
- 10
- Issue
- 2
- Pages
- 264-270
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W1968128732
- Cited by
- 230
- References
- 0
- FWCI
- 13.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo, three-dimensional microscopy of trabecular bone. https://app.cochat.ai/papers/10.1002/jbmr.5650100213
- The paper
- Dr. Kinney, J. H., Lane, N. E., & Haupt, D. L. (1995). In vivo, three-dimensional microscopy of trabecular bone. Journal of Bone and Mineral Research. https://doi.org/10.1002/jbmr.5650100213
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.