The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
A microtomographic system for the nondestructive evaluation of bone architecture
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · Proceedings of the 14th annual conference on Computer graphics and interactive techniques · doi:10.1145/37401.37422 · Cited by 10,104
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · ACM SIGGRAPH Computer Graphics · doi:10.1145/37402.37422 · Cited by 8,647
Parfitt, A. M., Drezner, M. K., Glorieux, F. H., Kanis, J. A., Malluche, H., Meunier, P. J., Ott, S. M., & Recker, R. R. (1987) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650020617 · Cited by 5,016
Bone Histomorphometry : Standardization of Nomenclature, Symbols, and Units
PARFITT, A. M., Drezner, M. K., Glorieux, F. H., Kanis, J. А., Malluche, H. H., Meunier, P. J., Ott, S. M., & Recker, R. R. (1987) · Journal of Bone and Mineral Research · Cited by 3,258
Consensus development conference: Diagnosis, prophylaxis, and treatment of osteoporosis
(1993) · The American Journal of Medicine · doi:10.1016/0002-9343(93)90218-e · Cited by 2,874
Bone histomorphometry : techniques and interpretation
Recker, R. R. (1983) · CRC Press eBooks · Cited by 1,158
The direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Kopera, H., & Ziegler, R. (1989) · Klinische Wochenschrift · doi:10.1007/bf01719785 · Cited by 749
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
Cited by
Weissleder, R., & Mahmood, U. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma19316 · Cited by 1,315
Quantification of Bone Microarchitecture with the Structure Model Index
HILDEBRAND, T., & RÜEGSEGGER, P. (1997) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/01495739708936692 · Cited by 1,051
Self-citationBobbert, F. S. L., Lietaert, K., Eftekhari, A. A., Pouran, B., Ahmadi, S. M., Weinans, H., & Zadpoor, A. A. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.024 · Cited by 873
TRANCE/RANKL knockout mice are protected from bone erosion in a serum transfer model of arthritis.
Pettit, A. R., Ji, H., von Stechow, D., Müller, R., Goldring, S. R., Choi, Y., Benoist, C., & Gravallese, E. M. (2001) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)63016-7 · Cited by 807
Self-citationBuie, H. R., Campbell, G. M., Klinck, R. J., MacNeil, J. A., & Boyd, S. K. (2007) · Bone · doi:10.1016/j.bone.2007.07.007 · Cited by 601
Metadata
- Authors
- Rüegsegger, P., Koller, B., & Müller, R.
- Venue
- Calcified Tissue International
- Published
- 1996-01
- Volume
- 58
- Issue
- 1
- Pages
- 24-29
- ISSN
- 0171-967X (ISSN-L)
- 1432-0827
- OpenAlex
- W2040873725
- Cited by
- 893
- References
- 21
- FWCI
- 25.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A microtomographic system for the nondestructive evaluation of bone architecture. https://app.cochat.ai/papers/10.1007/bf02509542
- The paper
- Rüegsegger, P., Koller, B., & Müller, R. (1996). A microtomographic system for the nondestructive evaluation of bone architecture. Calcified Tissue International. https://doi.org/10.1007/bf02509542
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.