CoChat

Bone mass, areal, and volumetric bone density are equally accurate, sensitive, and specific surrogates of the breaking strength of the vertebral body: An in vitro study

Tabensky, Aaron D., Deluca, Vanessa, Briganti, Esther, Seeman, Ego, Williams, John · 1996 · Journal of Bone and Mineral Research
Cited by 110

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The validity of the bone mineral density (BMD) measurement depends on its accuracy as a predictor of the breaking strength of bone. As the breaking strength is proportional to the square of the apparent density, a small error in the calculation of BMD may result in a larger error in the predicted bone strength. The aims of this study were (i) to determine whether inaccuracies in the measurement of the dimensions, projected area, and volume of the vertebral body (used to derive the areal and volumetric BMD) result in errors in the predicted breaking strength and (ii) to compare the accuracy, sensitivity, and specificity of bone mineral content (BMC), areal BMD, volumetric BMD, and volumetric bone mineral apparent density (BMAD) as surrogates of bone strength. We measured the BMC (by densitometry), dimensions and volume (using calipers, densitometry, the Carter et al. and Peel and Eastell methods), and breaking strength (using the Instron 1114 apparatus, Newtons, N) of 22 vertebral body specimens. All methods resulted in errors in height, width, and depth between −11.3 + 1.0 and 30.4 + 1.8% relative to the “gold” standard caliper method. The vertebral body volume (of 38.0 + 12 cm3) measured by submersion was used as the gold standard to derive the volumetric BMD gold standard (of 0.162 + 0.01 g/cm3). All methods, except the Peel and Eastell method, resulted in errors ranging between −10.7 + 1.5 and 56.9 + 3.4% in vertebral body volume and −35.6 + 1.5 to 12.6 + 1.8% in volumetric BMD (allp < 0.0005). The same absolute value for volumetric BMD predicted a breaking strength that differed according to the method used to derive BMD. For example, a volumetric BMD of 0.162 g/cm3 predicted a breaking strength of 6208 N (submersion method), 5473 N (caliper method), 6095 N (Peel and Eastell method), 7697 N (DXA method), and 9470 N (Carter et al. method). The mean volumetric BMD derived by each method differed (0.181,0.165,0.133, and 0.104 g/cm3, respectively). However, all were accurate; each predicted a similar breaking strength (6177, 6217, 6209, and 6221 N respectively). Likewise, breaking strengths predicted by the mean BMC, areal BMD by calipers, and areal BMD by dual-energy X-ray absorptiometry (DXA) were 6267,6214, and 6244 N, respectively. The methods were equally sensitive; a 1 standard deviation (SD) decrease in volumetric BMD resulted in a similar decrease in the breaking strength of 1818 (caliper), 2080 (Peel and Eastell), 2001 (DXA), and 1625 N (BMAD by Carter et al). A 1 SD decrease in BMC, areal BMD (using calipers) and areal BMD (using DXA) predicted a decrease in the breaking strength of 2019,1738, and 1825 N, respectively. All methods were equally specific; the variance in bone strength explained by bone mass did not differ for volumetric BMD (38–61% depending on the method), BMC (58%), or areal BMD (48%). In conclusion, despite errors in the measurement of the dimensions of the vertebral body, bone mass, areal, and volumetric bone density are equally accurate, sensitive, and specific surrogates of the breaking strength of bone in vitro.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbmr.5650111221

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 110

Metadata

Authors
Tabensky, A. D., Deluca, V., Briganti, E., Seeman, E., & Williams, J.
Venue
Journal of Bone and Mineral Research
Published
1996-12-01
Volume
11
Issue
12
Pages
1981-1988
ISSN
  • 0884-0431 (ISSN-L)
  • 1523-4681
OpenAlex
W2022006007
Cited by
110
References
3
FWCI
6.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.