CoChat

Accurate reaction barrier heights of pericyclic reactions: Surprisingly large deviations for the CBS‐QB3 composite method and their consequences in DFT benchmark studies

Open access
Karton, Amir, Goerigk, Lars · 2015 · Journal of Computational Chemistry
Cited by 147

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Accurate barrier heights are obtained for the 26 pericyclic reactions in the BHPERI dataset by means of the high‐level W n‐F12 thermochemical protocols. Very often, the complete basis set (CBS)‐type composite methods are used in similar situations, but herein it is shown that they in fact result in surprisingly large errors with root mean square deviations (RMSDs) of about 2.5 kcal mol−1. In comparison, other composite methods, particularly G4‐type and estimated coupled cluster with singles, doubles, and quasiperturbative triple excitations [CCSD(T)/CBS] approaches, show deviations well below the chemical‐accuracy threshold of 1 kcal mol−1. With the exception of SCS‐MP2 and the herein newly introduced MP3.5 approach, all other tested Møller‐Plesset perturbative procedures give poor performance with RMSDs of up to 8.0 kcal mol−1. The finding that CBS‐type methods fail for barrier heights of these reactions is unexpected and it is particularly troublesome given that they are often used to obtain reference values for benchmark studies. Significant differences are identified in the interpretation and final ranking of density functional theory (DFT) methods when using the original CBS‐QB3 rather than the new W n‐F12 reference values for BHPERI. In particular, it is observed that the more accurate W n‐F12 benchmark results in lower statistical errors for those methods that are generally considered to be robust and accurate. Two examples are the PW6B95‐D3(BJ) hybrid‐meta‐general‐gradient approximation and the PWPB95‐D3(BJ) double‐hybrid functionals, which result in the lowest RMSDs of the entire DFT study (1.3 and 1.0 kcal mol−1, respectively). These results indicate that CBS‐QB3 should be applied with caution in computational modeling and benchmark studies involving related systems. © 2015 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jcc.23837

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 147

Metadata

Authors
Karton, A., & Goerigk, L.
Venue
Journal of Computational Chemistry
Publisher
Wiley
Published
2015-02-03
Volume
36
Issue
9
Pages
622-632
ISSN
  • 0192-8651 (ISSN-L)
  • 1096-987X
OpenAlex
W2098963943
Cited by
147
References
3
FWCI
9.17
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accurate reaction barrier heights of pericyclic reactions: Surprisingly large deviations for the CBS‐QB3 composite method and their consequences in DFT benchmark studies. https://app.cochat.ai/papers/10.1002/jcc.23837
The paper
Karton, A., & Goerigk, L. (2015). Accurate reaction barrier heights of pericyclic reactions: Surprisingly large deviations for the CBS‐QB3 composite method and their consequences in DFT benchmark studies. Journal of Computational Chemistry. https://doi.org/10.1002/jcc.23837

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.