The DOI matches its Crossref record.
Microtiter plate assay for phagocyte‐derived Taurine‐chloramines
Abstract
Despite their potential importance, the role of phagocyte‐derived chloramines (“longlived oxidants”) has not yet been investigated in inflammatory or infectious diseases. We have developed a sensitive spectrophotometric microtiter plate assay for chloramines based on their capacity to oxidize potassium iodide (Kl). Consistant levels of endogenous chloramines were detected in normal human polymorphonuclear neutrophil (PMN) supernatants after stimulation by phorbol myristate acetate (PMA) or opsonized zymosan. Exogenous taurine strongly enhanced chloramine secretion and was used to quantify the chlorinating potential of PMN. Taurine‐chloramines were also detectable in monocyte supenatants, although in smaller amounts. The specificity of the KI assay was assessed both in terms of effect of compounds inhibiting (KBr) or interacting with (sodium azide and catalase) chloramine formation and by showing that PMN from patients with chronic granulomatous disease, due to a hereditary lack of oxidative response capacity, were unable to produce chloramines. Taurine‐chloramine levels secreted by PMA (but not zymosan)‐stimulated PMN were closely related to the cellular luminol‐amplified chemiluminescence (CL) responses although the CL assay failed to detect chloramines in PMN supernatants. We consider that this KI assay should be of use in studying the role of long‐lived phagocyte‐derived oxidants in clinical medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advanced oxidation protein products as a novel marker of oxidative stress in uremia
Witko-Sarsat, V., Friedlander, M., Capeillère-Blandin, C., Nguyen-Khoa, T., Nguyen, A. T., Zingraff, J., Jungers, P., & Descamps-Latscha, B. (1996) · Kidney International · doi:10.1038/ki.1996.186 · Cited by 1,999
Self-citationWitko-Sarsat, V., Friedlander, M., Khoa, T. N., Capeillère-Blandin, C., Nguyen, A. T., Canteloup, S., Dayer, J.-M., Jungers, P., Drüeke, T., & Descamps-Latscha, B. (1998) · The Journal of Immunology · doi:10.4049/jimmunol.161.5.2524 · Cited by 878
Self-citationThornalley, P. J., & Rabbani, N. (2014) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2013.03.025 · Cited by 133
Daumer (2000) · doi:10.1074/jbc.m002003200 · Cited by 65
School of Diagnostic and Applied Health Science, F. O. H. S., Budin, S. B., Jia Hui, K., School of Diagnostic and Applied Health Science, F. O. H. S., Jia Hui, L., School of Diagnostic and Applied Health Science, F. O. H. S., RamaLingam, A., School of Diagnostic and Applied Health Science, F. O. H. S., Jubaidi, F. F., School of Diagnostic and Applied Health Science, F. O. H. S., et al. (2017) · Malaysian Journal of Medical Sciences · doi:10.21315/mjms2017.24.6.6 · Cited by 35
Metadata
- Authors
- Witko, V., Nguyen, A. T., & Descamps‐Latscha, B.
- Venue
- Journal of Clinical Laboratory Analysis
- Publisher
- Wiley
- Published
- 1992-01
- Volume
- 6
- Issue
- 1
- Pages
- 47-53
- ISSN
- 0887-8013 (ISSN-L)
- 1098-2825
- OpenAlex
- W2088381903
- Cited by
- 170
- References
- 0
- FWCI
- 0.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microtiter plate assay for phagocyte‐derived Taurine‐chloramines. https://app.cochat.ai/papers/10.1002/jcla.1860060110
- The paper
- Witko, V., Nguyen, A. T., & Descamps‐Latscha, B. (1992). Microtiter plate assay for phagocyte‐derived Taurine‐chloramines. Journal of Clinical Laboratory Analysis. https://doi.org/10.1002/jcla.1860060110
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.