Fetal head and abdominal circumferences: I. Evaluation of measurement errors
The DOI matches its Crossref record.
Abstract
Several sources of error associated with the measurement of fetal head and abdominal circumferences (HC, AC) were examined using dynamic image ultrasound. Statistically significant systematic intraobserver errors were not seen unless technical differences in the images were present (HC only) and the range for random errors was 4–5% (2 SD) for both measurements. Although differences in the procedures used to acquire images for measurement had some effect on accuracy (HC only), the primary source of variations in measurements made by different investigators was the measurement methods. Different measuring devices gave different results and different investigators used the same devices differently. Under optimal measuring conditions, the interobserver error for experienced investigators was 1.2 (±4.3 SD)% for HC and 2.4 (±1.6 SD)% for AC. Comparison of prenatal and postnatal measurements indicated that there were no systematic differences for HC but for AC, the prenatal measurements were 6% greater. Random differences were ±6% (2 SD) for HC and ±13% (2 SD) for AC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chibueze, E. C., Parsons, A. J. Q., Lopes, K. D. S., Yo, T., Swa, T., Nagata, C., Horita, N., Morisaki, N., Balogun, O. O., Dagvadorj, A., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-01991-y · Cited by 287
Fetal head circumference: relation to menstrual age
Hadlock, F., Deter, R., Harrist, R., & Park, S. (1982) · American Journal of Roentgenology · doi:10.2214/ajr.138.4.649 · Cited by 196
Self-citationIntra‐ and interobserver variability in fetal ultrasound measurements
Sarris, I., Ioannou, C., Chamberlain, P., Ohuma, E., Roseman, F., Hoch, L., Altman, D. G., Papageorghiou, A. T., & for the International Fetal and Newborn Growth Consortium for the 21 Century (INTERGROWTH‐21) (2012) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.10082 · Cited by 195
The importance of quality management in fetal measurement
Dudley, N. J., & Chapman, E. (2002) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.0960-7692.2001.00549.x · Cited by 94
“A number of groups have reported interobserver variability (coefficient of variation) in the range 2–3% 16–18 .”
BackgroundNapolitano, R., Donadono, V., Ohuma, E. O., Knight, C. L., Wanyonyi, S. Z., Kemp, B., Norris, T., & Papageorghiou, A. T. (2016) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.15956 · Cited by 54
Metadata
- Authors
- Deter, R. L., Harrist, R. B., Hadlock, F. P., & Carpenter, R. J.
- Venue
- Journal of Clinical Ultrasound
- Publisher
- Wiley
- Published
- 1982-10
- Volume
- 10
- Issue
- 8
- Pages
- 357-363
- ISSN
- 0091-2751 (ISSN-L)
- 1097-0096
- OpenAlex
- W2090027120
- Cited by
- 47
- References
- 0
- FWCI
- 3.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.