Cited by 94Prenatal Screening and DiagnosticsUltrasound in Clinical ApplicationsReliability and Agreement in Measurement

The importance of quality management in fetal measurement

Dudley, N. J., Chapman, E.·2002·Ultrasound in Obstetrics & Gynecology

Abstract

OBJECTIVES: The aims of this study were to evaluate factors contributing to inaccuracy in fetal measurements and to assess the clinical importance of measurement quality. METHODS: One hundred images of biparietal diameter (BPD), head circumference (HC) and abdominal circumference (AC) measurements were collected from six centers (1800 measurements); the proportion meeting quality criteria was assessed. Four hundred images of AC were collected from one center, each image measured by ellipse fitting and tracing methods; clinical agreement between the methods was assessed. Fetal weight estimation (EFW) errors were compared between quality controlled and non-quality controlled studies. Images of three ACs on each of 400 fetuses were collected; where one measurement failed to meet quality criteria, it was compared with an optimal measurement on the same fetus. RESULTS: Eighty-nine percent, 87% and 60% of BPD, HC and AC, respectively, met all quality criteria. Limits of agreement between ellipse and traced AC were -4.7 mm to 12.5 mm; 22% of sections were non-elliptical. EFW errors were significantly different but were confounded by differences in time to delivery. Limits of agreement between optimal and suboptimal AC measurements were -15.1 mm to 7.7 mm. CONCLUSIONS: AC quality criteria are less easily recognized and obtained than those for head measurements; training, adherence to protocols and audit are important. Differences between ellipse and traced AC may not justify the use of separate charts; the number of non-elliptical sections suggests that ellipse fitting is not appropriate. Comparison between EFW errors is not a suitable tool for audit. Failure to meet quality criteria results in clinically significant errors.

Integrity signals

Registry

Crossref · 10.1046/j.0960-7692.2001.00549.x

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Incorrect fetal abdominal circumference measurement may lead to inaccurate fetal weight estimation and further increase the risk of misdiagnosis.

    “In clinical examination and diagnosis, incorrect fetal AC measurement may lead to inaccurate fetal weight estimation and further increase the risk of misdiagnosis [98].”

    From Deep Learning in Medical Ultrasound Analysis: A Review (2019) · cites this paper as [98]

The citation lists haven’t been fetched yet

References 19 · Cited by 94

Authors
Dudley, N. J., & Chapman, E.
Affiliations
Nottingham City Hospital (GB)
Corresponding author
Dudley, N. J.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2002-02
Volume
19
Issue
2
Pages
190-196
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2082941960
Cited by
94
References
19
Citations by year
2026: 1 · 2025: 2 · 2024: 3 · 2023: 7 · 2022: 2 · 2021: 8 · 2020: 5 · 2019: 6 · 2018: 4 · 2017: 8 · 2016: 1 · 2015: 3 · 2014: 5 · 2013: 5 · 2012: 4
FWCI
2.10
Type
journal article
Language
en
Open access
closed
Locations
  • Ultrasound in Obstetrics and Gynecology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
Keywords
fetal biometry, measurement quality, quality control, biparietal diameter, head circumference, abdominal circumference, fetal weight estimation, ellipse fitting, measurement error
MeSH terms
Abdomen, Female, Fetus, Gestational Age, Head, Humans, Pregnancy, Quality Control, Ultrasonography, Prenatal, Fetal Weight

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review