Abstract
OBJECTIVES: The aims of this study were to evaluate factors contributing to inaccuracy in fetal measurements and to assess the clinical importance of measurement quality. METHODS: One hundred images of biparietal diameter (BPD), head circumference (HC) and abdominal circumference (AC) measurements were collected from six centers (1800 measurements); the proportion meeting quality criteria was assessed. Four hundred images of AC were collected from one center, each image measured by ellipse fitting and tracing methods; clinical agreement between the methods was assessed. Fetal weight estimation (EFW) errors were compared between quality controlled and non-quality controlled studies. Images of three ACs on each of 400 fetuses were collected; where one measurement failed to meet quality criteria, it was compared with an optimal measurement on the same fetus. RESULTS: Eighty-nine percent, 87% and 60% of BPD, HC and AC, respectively, met all quality criteria. Limits of agreement between ellipse and traced AC were -4.7 mm to 12.5 mm; 22% of sections were non-elliptical. EFW errors were significantly different but were confounded by differences in time to delivery. Limits of agreement between optimal and suboptimal AC measurements were -15.1 mm to 7.7 mm. CONCLUSIONS: AC quality criteria are less easily recognized and obtained than those for head measurements; training, adherence to protocols and audit are important. Differences between ellipse and traced AC may not justify the use of separate charts; the number of non-elliptical sections suggests that ellipse fitting is not appropriate. Comparison between EFW errors is not a suitable tool for audit. Failure to meet quality criteria results in clinically significant errors.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Incorrect fetal abdominal circumference measurement may lead to inaccurate fetal weight estimation and further increase the risk of misdiagnosis.
“In clinical examination and diagnosis, incorrect fetal AC measurement may lead to inaccurate fetal weight estimation and further increase the risk of misdiagnosis [98].”
From Deep Learning in Medical Ultrasound Analysis: A Review (2019) · cites this paper as [98]
The citation lists haven’t been fetched yet
References 19 · Cited by 94
- Authors
- Dudley, N. J., & Chapman, E.
- Affiliations
- Nottingham City Hospital (GB)
- Corresponding author
- Dudley, N. J.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2002-02
- Volume
- 19
- Issue
- 2
- Pages
- 190-196
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2082941960
- Cited by
- 94
- References
- 19
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 3 · 2023: 7 · 2022: 2 · 2021: 8 · 2020: 5 · 2019: 6 · 2018: 4 · 2017: 8 · 2016: 1 · 2015: 3 · 2014: 5 · 2013: 5 · 2012: 4
- FWCI
- 2.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Ultrasound in Obstetrics and Gynecology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- fetal biometry, measurement quality, quality control, biparietal diameter, head circumference, abdominal circumference, fetal weight estimation, ellipse fitting, measurement error
- MeSH terms
- Abdomen, Female, Fetus, Gestational Age, Head, Humans, Pregnancy, Quality Control, Ultrasonography, Prenatal, Fetal Weight
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review