Ultrasound of normal skin
The DOI matches its Crossref record.
Abstract
The authors have used a commercially available real‐time sector scanner and a 10‐MHz probe with a built‐in water path for B‐mode imaging of the normal skin. Measurements have been performed in 10 volunteers at 18 sites on the body surface. Normal skin thickness ranges from 1.4 mm at the dorsal aspect of hand to 4.8 mm at the heel. Clinical applications of B‐mode imaging of the skin are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Koo, J., MacEwan, M. R., Kang, S.-K., Won, S. M., Stephen, M., Gamble, P., Xie, Z., Yan, Y., Chen, Y.-Y., Shin, J., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0196-2 · Cited by 496
Choi, Y. S., Hsueh, Y.-Y., Koo, J., Yang, Q., Avila, R., Hu, B., Xie, Z., Lee, G., Ning, Z., Liu, C., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19660-6 · Cited by 292
Olsen, L. O., Takiwaki, H., & Serup, J. (1995) · Skin Research and Technology · doi:10.1111/j.1600-0846.1995.tb00021.x · Cited by 96
Metadata
- Authors
- Fornage, B. D., & Deshayes, J.
- Venue
- Journal of Clinical Ultrasound
- Publisher
- Wiley
- Published
- 1986-10
- Volume
- 14
- Issue
- 8
- Pages
- 619-622
- ISSN
- 0091-2751 (ISSN-L)
- 1097-0096
- OpenAlex
- W2078496790
- Cited by
- 70
- References
- 0
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasound of normal skin. https://app.cochat.ai/papers/10.1002/jcu.1870140808
- The paper
- Fornage, B. D., & Deshayes, J. (1986). Ultrasound of normal skin. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.1870140808
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.